Fuseholders

Image Part Number Description / PDF Quantity Rfq
03453HS2ZX010

03453HS2ZX010

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

868-062-000

868-062-000

Wickmann / Littelfuse

FUSE HOLDER BLADE 32V PANEL MNT

718

696101000002

696101000002

Würth Elektronik Midcom

FUSEHOLDER BLOCKS - PCB - CLIP C

0

LPA-01B-14Y

LPA-01B-14Y

OptiFuse

1-1/4"X1/4" FUSEHOLDER,20A-14AWG

725

BK/1A3400-10

BK/1A3400-10

PowerStor (Eaton)

FUSE CLIP CARTRIDGE 30A PCB

19000

BK/HTB-48M-R

BK/HTB-48M-R

PowerStor (Eaton)

FUSE HLDR CART 250V 16A PNL MNT

0

LPM-01B-12OR

LPM-01B-12OR

OptiFuse

MINI FUSEHOLDER, 30A-12AWG ORG

6317

LFG480303SQDINR

LFG480303SQDINR

Wickmann / Littelfuse

FUSE BLOK CART 480V 30A DIN RAIL

21

03420012H

03420012H

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

446

04820020ZXB

04820020ZXB

Wickmann / Littelfuse

FUSE HOLDER BLADE 125V 15A PCB

0

LPS-12C-16R

LPS-12C-16R

OptiFuse

MINI LP FUSEHOLDER-CLEAR, 16AWG

0

0PTF0045M

0PTF0045M

Wickmann / Littelfuse

FUSE HOLDER CARTRIDGE PCB

0

L60030M1PQ

L60030M1PQ

Wickmann / Littelfuse

FUSE BLOCK CART 600V 30A CHASSIS

314438

0031.1901

0031.1901

Schurter

FUSEHOLDER FOR 5X20 PNL MNT

114

LPM-01B-20B

LPM-01B-20B

OptiFuse

MINI FUSEHOLDER,7.5A-20AWG BLACK

0

0751.0141

0751.0141

Schurter

FUSE CLIP CARTRIDGE 600V 16A PCB

239

BK/HTC-30M

BK/HTC-30M

PowerStor (Eaton)

FUSE HLDR CART 250V 10A PNL MNT

5694

PMC-DS-05-SOR

PMC-DS-05-SOR

OptiFuse

5 X 20 MM - DRIVER/ SCREW,

244

FX0430/63

FX0430/63

Bulgin

FUSE HLDR CART 250V 10A PNL MNT

0

BK/S-8102-2

BK/S-8102-2

PowerStor (Eaton)

FUSE BLOCK CART 300V CHASS MNT

66

Fuseholders

1. Overview

Fuseholders are mechanical devices designed to safely house and connect fuses into electrical circuits. They ensure reliable mounting, electrical continuity, and safe isolation of fuses during overcurrent protection. As critical components in circuit protection systems, fuseholders prevent equipment damage and fire hazards by enabling controlled interruption of excessive current flow. Their importance spans industries such as power distribution, automotive, and industrial automation, where electrical safety and system reliability are paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Panel Mount FuseholdersEnclosed design with front-accessible fuse compartmentIndustrial control panels, HVAC systems
Base Mount FuseholdersModular design with removable fuse basePower distribution units, electrical substations
Cartridge FuseholdersCylindrical design for DIN-rail mountingProcess automation systems, machinery
SMT (Surface Mount) FuseholdersMiniaturized PCB-mount designConsumer electronics, telecommunications

3. Structure and Components

Typical fuseholders consist of: - Insulating housing (thermoplastic/phenolic resin) - Contact springs (phosphor bronze or beryllium copper) - Fuse retention mechanism (screw/clamp terminals) - Terminal connections (solder tags, PCB pins, or cable lugs) - Arc suppression chamber (ceramic/insulating barriers) The design ensures mechanical stability, low contact resistance (<10m ), and dielectric strength up to 2500VAC.

4. Key Technical Specifications

ParameterTypical RangeImportance
Voltage Rating6-1000V AC/DCDetermines circuit compatibility
Current Rating0.5-630ADefines maximum operational current
Breaking Capacity10kA-50kASafety during fault conditions
Response Time1ms-10sProtection speed for sensitive components
Temperature Range-40 C to +125 CEnvironmental reliability
IP RatingIP20-IP67Protection against dust/water ingress

5. Application Fields

  • Energy: Solar inverters, battery management systems
  • Automotive: EV charging stations, ECU protection
  • Industrial: PLC control circuits, motor drives
  • Telecom: 5G base stations, network switches
  • Aerospace: Avionics power distribution

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesNotable Features
LittelfusePOLO Panel MountModular design with visual indicators
MersenActi 9 seriesHigh breaking capacity (100kA)
EatonCircuit Protection EnclosuresUL94 V-0 rated materials
Bel Fuse0ZC SeriesSurface-mount with over-temperature cutoff

7. Selection Recommendations

Key considerations include: - Matching voltage/current ratings with system requirements - Environmental factors (temperature, vibration, humidity) - Accessibility requirements for fuse replacement - Compliance with standards (UL/IEC/EN) - Short-circuit current capacity of the installation - Mounting orientation and space constraints

Industry Trends and Future Outlook

Emerging trends include: - Miniaturization for EV and portable electronics - Integration with smart monitoring systems (IoT-enabled fuseholders) - Development of RoHS-compliant materials - High-voltage DC compatibility for renewable energy systems - Improved arc flash mitigation technologies The global market is projected to grow at 5.8% CAGR through 2027, driven by electric vehicle adoption and industrial automation demands.