Fuseholders

Image Part Number Description / PDF Quantity Rfq
03453LF7X

03453LF7X

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

0031.1071

0031.1071

Schurter

FUSE HLDR CART 500V 6.3A PNL MNT

31

03453LS8HXNP

03453LS8HXNP

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

0

L60030C3SQDINR

L60030C3SQDINR

Wickmann / Littelfuse

FUSE BLOK CART 600V 30A DIN RAIL

8371206

LPR-02B-16B-CU

LPR-02B-16B-CU

OptiFuse

ATO/ATC #16AWG-15A Bare Copper

403

03453RF1ZX010

03453RF1ZX010

Wickmann / Littelfuse

FUSE HLDR CART 250V 20A PNL MNT

481

T60060-2SR

T60060-2SR

Eaton

FUSE BLOCK CART 600V 60A CHASSIS

0

01530002H

01530002H

Wickmann / Littelfuse

FUSE HOLDER BLADE 20A IN LINE

4917

01550900M

01550900M

Wickmann / Littelfuse

FUSE BLOK CARTRIDGE 125V 10A SMD

2151

LPR-02R-16R

LPR-02R-16R

OptiFuse

REG. FUSEHOLDER, 15A-16AWG RED

1795

03455RF8X

03455RF8X

Wickmann / Littelfuse

FUSE HLDR CART 250V 10A PNL MNT

0

0LEX00AAX

0LEX00AAX

Wickmann / Littelfuse

FUSE HLDR CART 600V 30A IN LINE

5

178.6152.2501

178.6152.2501

Wickmann / Littelfuse

FUSE HOLDER BLADE 80V CHASS MNT

0

BK/HFB

BK/HFB

PowerStor (Eaton)

FUSE HOLDER CART 32V 30A IN LINE

3700

CNR-03-CE

CNR-03-CE

OptiFuse

REGULAR FUSE CLIP, 30A MATTE

0

LPS-12C-12R

LPS-12C-12R

OptiFuse

MINI LP FUSEHOLDER-CLEAR, 12AWG

0

BLC-209

BLC-209

OptiFuse

FUSE BLOCK-LIMITER ANE/ANF, 800A

640

BLR-I-504

BLR-I-504

OptiFuse

REGULAR FUSE BLOCK, 4 POLE LED

554

PDM71001ZXM

PDM71001ZXM

Wickmann / Littelfuse

NEXT GEN HWB60 WITH TPAS

15

03455LF4X

03455LF4X

Wickmann / Littelfuse

FUSE HLDR CART 250V 10A PNL MNT

0

Fuseholders

1. Overview

Fuseholders are mechanical devices designed to safely house and connect fuses into electrical circuits. They ensure reliable mounting, electrical continuity, and safe isolation of fuses during overcurrent protection. As critical components in circuit protection systems, fuseholders prevent equipment damage and fire hazards by enabling controlled interruption of excessive current flow. Their importance spans industries such as power distribution, automotive, and industrial automation, where electrical safety and system reliability are paramount.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Panel Mount FuseholdersEnclosed design with front-accessible fuse compartmentIndustrial control panels, HVAC systems
Base Mount FuseholdersModular design with removable fuse basePower distribution units, electrical substations
Cartridge FuseholdersCylindrical design for DIN-rail mountingProcess automation systems, machinery
SMT (Surface Mount) FuseholdersMiniaturized PCB-mount designConsumer electronics, telecommunications

3. Structure and Components

Typical fuseholders consist of: - Insulating housing (thermoplastic/phenolic resin) - Contact springs (phosphor bronze or beryllium copper) - Fuse retention mechanism (screw/clamp terminals) - Terminal connections (solder tags, PCB pins, or cable lugs) - Arc suppression chamber (ceramic/insulating barriers) The design ensures mechanical stability, low contact resistance (<10m ), and dielectric strength up to 2500VAC.

4. Key Technical Specifications

ParameterTypical RangeImportance
Voltage Rating6-1000V AC/DCDetermines circuit compatibility
Current Rating0.5-630ADefines maximum operational current
Breaking Capacity10kA-50kASafety during fault conditions
Response Time1ms-10sProtection speed for sensitive components
Temperature Range-40 C to +125 CEnvironmental reliability
IP RatingIP20-IP67Protection against dust/water ingress

5. Application Fields

  • Energy: Solar inverters, battery management systems
  • Automotive: EV charging stations, ECU protection
  • Industrial: PLC control circuits, motor drives
  • Telecom: 5G base stations, network switches
  • Aerospace: Avionics power distribution

6. Leading Manufacturers and Products

ManufacturerKey Product SeriesNotable Features
LittelfusePOLO Panel MountModular design with visual indicators
MersenActi 9 seriesHigh breaking capacity (100kA)
EatonCircuit Protection EnclosuresUL94 V-0 rated materials
Bel Fuse0ZC SeriesSurface-mount with over-temperature cutoff

7. Selection Recommendations

Key considerations include: - Matching voltage/current ratings with system requirements - Environmental factors (temperature, vibration, humidity) - Accessibility requirements for fuse replacement - Compliance with standards (UL/IEC/EN) - Short-circuit current capacity of the installation - Mounting orientation and space constraints

Industry Trends and Future Outlook

Emerging trends include: - Miniaturization for EV and portable electronics - Integration with smart monitoring systems (IoT-enabled fuseholders) - Development of RoHS-compliant materials - High-voltage DC compatibility for renewable energy systems - Improved arc flash mitigation technologies The global market is projected to grow at 5.8% CAGR through 2027, driven by electric vehicle adoption and industrial automation demands.