Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
004373619

004373619

Altech Corporation

FUSENH1ARG250A690VAC 200KA ACFOR

0

004723246

004723246

Altech Corporation

FUSENH1GRM200A690VAC 550VDC200KA

0

10NZ01SC

10NZ01SC

Altech Corporation

FUSE CARTRIDGE 10A 440VAC/250VDC

0

004724218

004724218

Altech Corporation

FUSE 224A 690VAC 550VDC

0

004331018

004331018

Altech Corporation

FUSE 6A 690VAC/440VDC

0

002212007

002212007

Altech Corporation

FUSE CARTRIDGE 40A 400VAC/250VDC

0

004322001

004322001

Altech Corporation

FUSE 2A 500VAC 315VDC PINK

0

004335115

004335115

Altech Corporation

FUSENH3ARS110560A690VAC 440VDCFO

0

004184418

004184418

Altech Corporation

FUSENH1AMM224A690VAC KOMBI

0

20C10X38AM

20C10X38AM

Altech Corporation

FUSE CARTRIDGE 20A 400VAC 5AG

40

004303514

004303514

Altech Corporation

FUSENH1ARG100A1000VAC 200KA ACFO

0

63NH00AM-6

63NH00AM-6

Altech Corporation

FUSE MOTORPROTECTION 3 NH0063A66

0

004265005

004265005

Altech Corporation

FUSEHVVVC537MM6A 20/36KVD=53STRI

0

002315101

002315101

Altech Corporation

FUSE CRTRDGE 125A 500VAC/400VDC

0

004717235

004717235

Altech Corporation

FUSENH4AGRM1500A500VAC 200KA ACF

0

004332208

004332208

Altech Corporation

FUSE 40A 690VAC/440VDC

0

004721208

004721208

Altech Corporation

FUSE 32A 690VAC 550VDC

0

004196323

004196323

Altech Corporation

FUSENH3GGM200A690VAC KOMBIISOLAT

0

004743627

004743627

Altech Corporation

FUSENH1ARG550A690VAC 200KA ACFOR

0

004110303

004110303

Altech Corporation

FUSENH1CGPVM63A750VDC

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems