Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
004255110

004255110

Altech Corporation

FUSEHVVVC292MM32A 10/24KVD=68STR

0

004116105

004116105

Altech Corporation

FUSENH4GGS150900A500VAC

0

004237514

004237514

Altech Corporation

FUSEHVVVTE442MM80A 6/12KVD=68STR

0

004235511

004235511

Altech Corporation

FUSEHVVVC442MM40A 6/12KVD=53STRI

0

004257512

004257512

Altech Corporation

FUSEHVVVTE537MM50A 10/24KVD=68ST

0

004734228

004734228

Altech Corporation

FUSE 630A 1.2KVAC

0

004115408

004115408

Altech Corporation

FUSENH3GTRM577A400KVA 400VACKOMB

0

002645013

002645013

Altech Corporation

FUSE 25A 690VAC/500VDC

0

004225006

004225006

Altech Corporation

FUSEHVVVC192MM10A 3/7.2KVD=53MMS

0

6D33FB-7

6D33FB-7

Altech Corporation

FUSE DIAZED DIII 6 AMP 750V FAST

0

004304125

004304125

Altech Corporation

FUSENH2ARS110450A1000VAC 200KA A

0

004225505

004225505

Altech Corporation

FUSEHVVVC292MM6A 3/7.2KVD=53MMST

0

004743727

004743727

Altech Corporation

FUSENH1ARS110550A690VAC 200KA AC

0

004110485

004110485

Altech Corporation

FUSE 450A 1.1KVDC GPV TYPE

0

002625005

002625005

Altech Corporation

FUSE CARTRIDGE 6A 600VAC/700VDC

0

40NH00GR-6

40NH00GR-6

Altech Corporation

FUSE SQUARE 40A 660VAC RECT

0

004110533

004110533

Altech Corporation

FUSENH1CGRM50A1000VDC

0

004195320

004195320

Altech Corporation

FUSENH2GGM280A690VAC KOMBIISOLAT

0

004383114

004383114

Altech Corporation

FUSENH1ARS80100A690VAC 200KA ACV

0

004335111

004335111

Altech Corporation

FUSENH3ARS110400A690VAC 440VDCFO

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems