Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
SPXV020.L

SPXV020.L

Wickmann / Littelfuse

FUSE CARTRIDGE 20A 1.5KVDC

154

PSX3XLFL0900X

PSX3XLFL0900X

Wickmann / Littelfuse

FUSE SEMI 1500VDC 3XL SIZE 900A

4

JLLS1200XXP

JLLS1200XXP

Wickmann / Littelfuse

FUSE CRTRDGE 1.2KA 600VAC/300VDC

2

5NLE40E

5NLE40E

Wickmann / Littelfuse

FUSE CARTRIDGE 40A 5.5KVAC

0

0SLC002.T

0SLC002.T

Wickmann / Littelfuse

FUSE CARTRIDGE 2A 600VAC/170VDC

0

0JTD150.XXID

0JTD150.XXID

Wickmann / Littelfuse

FUSE CRTRDGE 150A 600VAC/500VDC

5

SPXI016.T

SPXI016.T

Wickmann / Littelfuse

FUSE SOLAR 1500VDC 16A

0

155.0892.6251

155.0892.6251

Wickmann / Littelfuse

FUSE SQUARE 250A 58VDC RECT

97

PSR030US0350Z

PSR030US0350Z

Wickmann / Littelfuse

FUSE SQUARE 350A 700VAC/600VDC

6

0LGR001.H

0LGR001.H

Wickmann / Littelfuse

FUSE CARTRIDGE 1A 300VAC

0

KLDR010.HXP

KLDR010.HXP

Wickmann / Littelfuse

FUSE CARTRIDGE 10A 600VAC/300VDC

0

0BLN005.T

0BLN005.T

Wickmann / Littelfuse

FUSE CARTRIDGE 5A 250VAC 5AG

0

0LMF1.25H

0LMF1.25H

Wickmann / Littelfuse

FUSE CARTRIDGE 1.25A 300VAC

0

SPXV003.T

SPXV003.T

Wickmann / Littelfuse

1500VDC 3 AMP PHOTOVOLTAIC FUSE

0

0FLQ.150T

0FLQ.150T

Wickmann / Littelfuse

FUSE CRTRDGE 150MA 500VAC/300VDC

0

0FLM02.8T

0FLM02.8T

Wickmann / Littelfuse

FUSE CRTRDGE 2.8A 250VAC/125VDC

0

CCMR020.TXP

CCMR020.TXP

Wickmann / Littelfuse

FUSE CARTRIDGE 20A 600VAC/500VDC

0

0SPF025.HXS

0SPF025.HXS

Wickmann / Littelfuse

FUSE CARTRIDGE 25A 1KVDC 5AG

0

157.5917.5351

157.5917.5351

Wickmann / Littelfuse

FUSE STRIP 35A 48VDC BOLT MOUNT

0

0LGR006.U

0LGR006.U

Wickmann / Littelfuse

FUSE CARTRIDGE 6A 300VAC

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems