Electrical, Specialty Fuses

Image Part Number Description / PDF Quantity Rfq
170M6246

170M6246

Eaton

FUSE SQUARE 800A 1.3KVAC RECT

0

170M4446

170M4446

Eaton

FUSE SQUARE 550A 1.3KVAC RECT

0

C14G16

C14G16

Eaton

FUSE CARTRIDGE 16A 690VAC

0

FWP-80A22F

FWP-80A22F

Eaton

FUSE CARTRIDGE 80A 700VAC/500VDC

0

FNQ-R-1-8/10

FNQ-R-1-8/10

Eaton

FUSE CARTRIDGE 1.8A 600VAC 5AG

0

170M3440

170M3440

Eaton

FUSE SQUARE 80A 1.3KVAC RECT

0

FNM-2-8/10

FNM-2-8/10

Eaton

FUSE CARTRIDGE 2.8A 250VAC 5AG

0

BK/GMT-1A

BK/GMT-1A

Eaton

FUSE INDICATING 1A 125VAC/60VDC

765

170M6709

170M6709

Eaton

FUSE SQUARE 550A 700VAC RECT

0

170M5460

170M5460

Eaton

FUSE SQUARE 500A 700VAC RECT

0

170M5191

170M5191

Eaton

FUSE SQUARE 350A 1.3KVAC RECT

0

56ET

56ET

Eaton

FUSE CARTRIDGE 56A 690VAC/500VDC

0

170M6313

170M6313

Eaton

FUSE 900A 690V 3E/91 AR UC

0

FNQ-15/100

FNQ-15/100

Eaton

FUSE CARTRIDGE 15MA 600VAC 5AG

0

FWP-50A14FA

FWP-50A14FA

Eaton

FUSE CARTRIDGE 50A 700VAC/800VDC

45

NITD25

NITD25

Eaton

FUSE CRTRDGE 25A 550VAC CYLINDR

0

170M4561

170M4561

Eaton

FUSE SQUARE 350A 700VAC RECT

0

170M6670

170M6670

Eaton

FUSE SQUARE 1.8KA 700VAC RECT

0

170M3608

170M3608

Eaton

FUSE SQUARE 40A 700VAC RECT

0

170M5766

170M5766

Eaton

FUSE SQUARE 1KA 700VAC RECT

0

Electrical, Specialty Fuses

1. Overview

Specialty fuses are precision-engineered circuit protection devices designed to safeguard electrical systems under specific abnormal conditions. Unlike general-purpose fuses, these devices offer tailored performance characteristics for specialized applications, including fast response times, high current interruption capabilities, and environmental resistance. Their importance in modern technology stems from their ability to protect sensitive electronics in critical systems such as medical devices, aerospace equipment, and renewable energy systems.

2. Main Types & Functional Classification

TypeFunctional FeaturesApplication Examples
Current-limiting FusesInterrupt fault currents within milliseconds using special fillersIndustrial motor drives, power distribution panels
Semiconductor FusesMaintain I2t values below 10A s for sensitive component protectionVariable frequency drives, battery management systems
Resettable Fuses (PTC)Automatically reset after fault clearanceConsumer electronics, automotive circuits
High-voltage FusesRated above 1kV with arc suppression technologyEV charging stations, grid-tied solar inverters
Time-delay FusesWithstand temporary current surges without trippingCompressors, transformers, medical imaging equipment

3. Structure & Composition

Typical construction includes: - Ceramic or glass reinforced polymer housing - Silver-plated copper/zinc alloy contacts - Specialized fuse element with controlled melting points - Arc quenching materials (e.g., silica sand) - Temperature-compensated mechanical linkages

4. Key Technical Parameters

ParameterImportanceTypical Range
Voltage RatingDefines maximum operating voltage32V-15kV
Current RatingDetermines normal operation threshold0.1A-2000A
Response TimeTime to interrupt fault current1ms-10s
I2t Let-throughEnergy withstand capability10-1000A s
Ambient Temperature RangeOperational environmental limits-55 C to +125 C

5. Application Fields

Primary industries include: - Industrial automation (PLC systems, CNC machines) - Automotive (EV battery protection, ADAS systems) - Renewable energy (solar inverters, wind turbine controls) - Medical equipment (MRI scanners, patient monitors) - Telecommunications (base stations, data center UPS)

6. Leading Manufacturers & Products

ManufacturerRepresentative ProductKey Features
LittelfuseSSL SeriesSurface-mount PTC for automotive applications
Bussmann170M SeriesCurrent-limiting semiconductor fuse
EatonXLP PlusHigh-performance current-limiting fuse
TE ConnectivityMini29Compact automotive blade fuse

7. Selection Guidelines

Key considerations: 1. Determine circuit voltage/current requirements 2. Analyze fault current characteristics 3. Consider environmental factors (temperature, vibration) 4. Verify compliance with standards (UL/IEC) 5. Evaluate replacement accessibility 6. Calculate required breaking capacity

8. Industry Trends

Emerging developments: - Graphene-enhanced PTC materials for faster response - Integration with IoT-enabled condition monitoring - Miniaturization for 5G infrastructure applications - Environmental compliance with RoHS/REACH standards - Development of hybrid fuse-circuit breaker devices - Increased adoption in EV battery management systems

RFQ BOM Call Skype Email
Top