Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
0915852

0915852

Phoenix Contact

CIRCUIT BREAKER THRM-MAG 16A

0

1020096

1020096

Phoenix Contact

CIRCUIT BRAKER 16A

2317

0915292

0915292

Phoenix Contact

CIR BRKR THRM-MAG 400MA LEVER

0

1020101

1020101

Phoenix Contact

CIRCUIT BRAKER 40A

2437

5650103

5650103

Phoenix Contact

CIR BRKR 300MA 250VAC 80VDC

0

0914963

0914963

Phoenix Contact

CIR BRKR 800MA 250VAC 65VDC

0

1019953

1019953

Phoenix Contact

CIRCUIT BREAKER 3A

2512

0914264

0914264

Phoenix Contact

CIR BRKR 1.5A 250VAC 65VDC

0

1019939

1019939

Phoenix Contact

CIRCUIT BRAKER 12A

1827

1020081

1020081

Phoenix Contact

CIRCUIT BRAKER 63A

237

5650102

5650102

Phoenix Contact

CIR BRKR 200MA 250VAC 80VDC

8

0914675

0914675

Phoenix Contact

CIR BRKR THRMMAG 5A 250VAC 65VDC

2

1020027

1020027

Phoenix Contact

CIRCUIT BRAKER 16A

255

0914196

0914196

Phoenix Contact

CIR BRKR THRM-MAG 200MA LEVER

4

0914581

0914581

Phoenix Contact

CIR BRKR 500MA 250VAC 65VDC

4

1019949

1019949

Phoenix Contact

CIRCUIT BRAKER 60A

2428

0914918

0914918

Phoenix Contact

CIR BRKR 200MA 250VAC 65VDC

0

0900317

0900317

Phoenix Contact

CIR BRKR SOLID STATE 3A 24VDC

0

5650142

5650142

Phoenix Contact

CIR BRKR 16A 250VAC 80VDC

0

1019920

1019920

Phoenix Contact

CIRCUIT BRAKER 16A

1228

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure