Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1019961

1019961

Phoenix Contact

CIRCUIT BRAKER 13A

1917

2907649

2907649

Phoenix Contact

CIR BRKR 63A 240VAC 125VDC

22152

1020037

1020037

Phoenix Contact

CIRCUIT BREAKER 1A

1

2800925

2800925

Phoenix Contact

CIR BRKR SOLID STATE 4A 24VDC

20

2907673

2907673

Phoenix Contact

CIR BRKR 63A 240VAC 125VDC

25

2800896

2800896

Phoenix Contact

CIR BRKR THRMMAG 6A 277VAC 80VDC

14

2800904

2800904

Phoenix Contact

CIR BRKR SOLID STATE 4A 24VDC

6

0916149

0916149

Phoenix Contact

CIR BRKR THRMMAG 3A 250VAC 65VDC

0

1019931

1019931

Phoenix Contact

CIRCUIT BREAKER 2A

15

2907560

2907560

Phoenix Contact

CIR BRKR THRMMAG 3A 277VAC 60VDC

0

0903024

0903024

Phoenix Contact

CIR BRKR SOLID STATE 2A 24VDC

14230

5531105

5531105

Phoenix Contact

CIRCUIT BREAKER THRM-MAG

182

2907562

2907562

Phoenix Contact

CIR BRKR THRMMAG 5A 277VAC 60VDC

2440

2800840

2800840

Phoenix Contact

CIR BRKR THRMMAG 5A 277VAC 50VDC

5

2907658

2907658

Phoenix Contact

CIR BRKR 8A 480VAC 125VDC

624

2800893

2800893

Phoenix Contact

CIR BRKR THRMMAG 3A 277VAC 80VDC

0

1019978

1019978

Phoenix Contact

CIRCUIT BRAKER 7A

1672

0916178

0916178

Phoenix Contact

CIR BRKR 6A 250VAC 65VDC

0

2907615

2907615

Phoenix Contact

CIR BRKR 10A 480VAC 125VDC

8

2907487

2907487

Phoenix Contact

CIR BRKR 10A 277VAC 60VDC

2

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top