Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
BK/CB181F-80

BK/CB181F-80

Eaton

CIRCUIT BREAKER 80A

0

CB185P-60

CB185P-60

Eaton

CIR BRKR 60A PUSH-RESET

0

CB255-25

CB255-25

Eaton

CIR BRKR 25A 32VDC PUSH-RESET

0

CB1921-25

CB1921-25

Eaton

CIR BRKR 25A PUSH-RESET

0

CB174-20

CB174-20

Eaton

CIR BRKR 20A PUSH-RESET

0

CB285F-120

CB285F-120

Eaton

CIR BRKR 120A PUSH-RESET

0

POLE98-30

POLE98-30

Eaton

4TH SWITCHED POLE UL98 30A COMPA

0

BK/CBC-15HB

BK/CBC-15HB

Eaton

CIR BRKR 15A 14V AUTOMATIC RESET

0

CB185-135

CB185-135

Eaton

CIR BRKR 135A PUSH-RESET

0

CBF-40

CBF-40

Eaton

CIR BRKR 40A 12VDC AUTO RESET

0

CBC-25B

CBC-25B

Eaton

CIR BRKR 25A AUTO RESET

0

CBC-50B

CBC-50B

Eaton

CIR BRKR 50A AUTO RESET

0

CBC-30

CBC-30

Eaton

CIR BRKR 30A AUTO RESET

0

BK/CB1911-20

BK/CB1911-20

Eaton

CIRCUIT BREAKER

0

BK/UCB-10

BK/UCB-10

Eaton

CIRCUIT BREAKER AUTOMOTIVE

0

CB185-40

CB185-40

Eaton

CIR BRKR 40A PUSH-RESET

0

CCPLP-2-20G-S

CCPLP-2-20G-S

Eaton

FUSE LP CCP CLASS G 20A P-SCREW

0

CB1911-15

CB1911-15

Eaton

CIR BRKR 15A AUTO RESET

0

CB185-120

CB185-120

Eaton

CIR BRKR 120A PUSH-RESET

0

BK/CB181F-120

BK/CB181F-120

Eaton

CIRCUIT BREAKE

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email
Top