Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
GMB631PC16

GMB631PC16

Carlo Gavazzi

CIR BRK THERM-M 16A 240VAC/60VDC

3

GSB631PC63

GSB631PC63

Carlo Gavazzi

MCB UL1077 C 1P 63A

17

GSB633PC3

GSB633PC3

Carlo Gavazzi

MCB UL1077 C 3P 3A

16

GMB633PC15

GMB633PC15

Carlo Gavazzi

CIR BRKR THERM-MAG 15A 240VAC

3

GMB63H3PC1

GMB63H3PC1

Carlo Gavazzi

CIR BRKR THERM-MAG 1A 480/277V

3

GMB631PC6

GMB631PC6

Carlo Gavazzi

CIR BRK THRM-MAG 6A 240VAC/60VDC

12

GMB631PC15

GMB631PC15

Carlo Gavazzi

CIR BRK THERM-M 15A 240VAC/60VDC

21

GMB63H2PC1.6

GMB63H2PC1.6

Carlo Gavazzi

CIR BRKR THERM-MAG 1.6A 480/277V

6

GMB632PC5

GMB632PC5

Carlo Gavazzi

CIR BRK THERM-M 5A 240VAC/125VDC

12

GMS-32H 13A

GMS-32H 13A

Carlo Gavazzi

MMS 32A HIGH BREAK 9-13A

4

GSB633PC4

GSB633PC4

Carlo Gavazzi

MCB UL1077 C 3P 4A

2

GMB631PC50

GMB631PC50

Carlo Gavazzi

CIR BRK THERM-M 50A 240VAC/60VDC

11

GMB632PC50

GMB632PC50

Carlo Gavazzi

CIR BRKR THERM 50A 240VAC/125VDC

19

GMB63H3PC30

GMB63H3PC30

Carlo Gavazzi

MCB HV UL489 C 3P 30A LUG T

7

GSB633PC25

GSB633PC25

Carlo Gavazzi

MCB UL1077 C 3P 25A

7

GMB63H3PC6

GMB63H3PC6

Carlo Gavazzi

CIR BRKR THERM-MAG 6A 480/277V

4

GSB633PC1

GSB633PC1

Carlo Gavazzi

MCB UL1077 C 3P 1A

10

GMB633PC30

GMB633PC30

Carlo Gavazzi

CIR BRKR THERM-MAG 30A 240VAC

4

GMB633PC16

GMB633PC16

Carlo Gavazzi

CIR BRKR THERM-MAG 16A 240VAC

4

GMB631PC30

GMB631PC30

Carlo Gavazzi

CIR BRK THERM-M 30A 240VAC/60VDC

4

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure