Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
1279060000

1279060000

Weidmuller

CIR BRKR THRM 8A 250VAC 65VDC

550

9926252006

9926252006

Weidmuller

CIR BRKR MAG-HYDR 6A 240VAC

25196

9926281010

9926281010

Weidmuller

CIR BRKR MAG-HYDR 10A 120VAC

720

9926251935

9926251935

Weidmuller

CIR BRKR MAG-HYDR 35A 80VDC

2

6720005362

6720005362

Weidmuller

CIR BRKR THRM 2A 24VDC SLD SWCH

2208

BR1C25UC

BR1C25UC

Weidmuller

CB MCB 489 1P C 25A ACDC

13484

1278970000

1278970000

Weidmuller

CIR BRKR THRM 2A 250VAC 65VDC

12130

BR1D8UC

BR1D8UC

Weidmuller

CB MCB 489 1P D 8A ACDC

1339

BR1C40UC

BR1C40UC

Weidmuller

CB MCB 489 1P C 40A ACDC

8122

9926252510

9926252510

Weidmuller

CIR BRKR MAG-HYDR 10A 480VAC

437

6720005302

6720005302

Weidmuller

CIR BRKR THRM 2A 24VDC SLD SWCH

1283

BR3D1UC

BR3D1UC

Weidmuller

CB MCB 489 3P D 1A ACDC

6140

BR1C4UC

BR1C4UC

Weidmuller

CB MCB 489 1P C 4A ACDC

250

BR1C1UC

BR1C1UC

Weidmuller

CB MCB 489 1P C 1A ACDC

10380

BR2D8UC

BR2D8UC

Weidmuller

CB MCB 489 2P D 8A ACDC

2219

1278850000

1278850000

Weidmuller

CIR BRKR THRM 200MA 250VAC 65VDC

1520

1279030000

1279030000

Weidmuller

CIR BRKR THRM 5A 250VAC 65VDC

0

9926252502

9926252502

Weidmuller

CIR BRKR MAG-HYDR 2A 480VAC

93

9926252506

9926252506

Weidmuller

CIR BRKR MAG-HYDR 6A 480VAC

9

9104153500

9104153500

Weidmuller

CIR BRKR THRMMAG 7A 250VAC 80VDC

558

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure