Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
4435.0055

4435.0055

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

6

4435.0117

4435.0117

Schurter

CIR BRKR THRM 4A 240VAC 60VDC

0

4400.0063

4400.0063

Schurter

CIR BRKR THRM 1A 240VAC 48VDC

358300

4435.0422

4435.0422

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

30

4400.0345

4400.0345

Schurter

CIR BRKR THRM 3A 240VAC 48VDC

96

4420.0281

4420.0281

Schurter

CIR BRKR THRM MAG 6A 480V 65V

8

4435.0092

4435.0092

Schurter

CIR BRKR THRM 12A 240VAC 60VDC

20

4435.0224

4435.0224

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

10

4430.1393

4430.1393

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

0

4420.0597

4420.0597

Schurter

CIR BRKR THRM MAG 12A 277V 65V

10

4430.0982

4430.0982

Schurter

CIR BRKR THRM 16A 240VAC 60VDC

10

4435.0582

4435.0582

Schurter

CIR BRKR THRM 100MA 240VAC 32VDC

16

4420.0497

4420.0497

Schurter

CIR BRKR THRM MAG 9A 480V 65V

0

4400.0132

4400.0132

Schurter

CIR BRKR THRM 1.5A 240VAC 48VDC

0

4420.023

4420.023

Schurter

CIR BRKR THRM MAG 2A 277V 65V

9

4435.0205

4435.0205

Schurter

CIR BRKR THRM 6A 240VAC 32VDC

6

4435.0581

4435.0581

Schurter

CIR BRKR THRM 200MA 240VAC 32VDC

0

4435.0168

4435.0168

Schurter

CIR BRKR THRM 5A 240VAC 60VDC

14

4430.2525

4430.2525

Schurter

CIR BRKR THRM 10A 240VAC 60VDC

9

4435.0034

4435.0034

Schurter

CIR BRKR THRM 900MA 240VAC 32VDC

20

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure