Circuit Breakers

Image Part Number Description / PDF Quantity Rfq
CPP11-51-4.00A-OB-V

CPP11-51-4.00A-OB-V

Sensata Technologies – Airpax

CIR BRKR MAG-HYDR 4A PUSH-PULL

0

9926251815

9926251815

Weidmuller

CIR BRKR MAG-HYDR 15A 125VDC

20660

MOCBM-PX-10A

MOCBM-PX-10A

OptiFuse

MAXI FUSE FOOTPRINT-TYPE II, 10A

0

4230-T130-K0CU-30A

4230-T130-K0CU-30A

E-T-A

CIR BRKR THERM 30A 480VAC/125VDC

1

106-M3-P30-8A

106-M3-P30-8A

E-T-A

CIR BRKR THRM 8A 250VAC 48VDC

0

4230-T120-K0DE-8A

4230-T120-K0DE-8A

E-T-A

CIR BRK THERM-M 8A 480VAC/125VDC

0

175-S0-050-2R

175-S0-050-2R

MP

HIGH AMP CB-TYPE III MANUAL 50A

31

ACBP-24-V-40A

ACBP-24-V-40A

OptiFuse

VER. BRACKET-TYPE I AUTO,40A 24V

0

C40A2P-GFI

C40A2P-GFI

American Electrical, Inc.

CIR BRKR MAG-HYDR 40A 240VAC

0

W28-XTBA-3

W28-XTBA-3

TE Connectivity Potter & Brumfield Relays

CIR BRKR THRM 3A 250VAC 32VDC

88

IULK11-1REC4-59-100.-01

IULK11-1REC4-59-100.-01

Sensata Technologies – Airpax

CIR BRKR MAG-HYDR 100A LEVER

0

MOCB-12-N-10A

MOCB-12-N-10A

OptiFuse

NO BRACKET-TYPE II MOD, 10A 12V

0

106-M2-P33-0.7A

106-M2-P33-0.7A

E-T-A

CIR BRKR THRM 700MA 250VAC 48VDC

0

QLB-253-11B3N-3BA

QLB-253-11B3N-3BA

Qualtek Electronics Corp.

CIR BRKR THRM 25A 250VAC 32VDC

9

4435.0309

4435.0309

Schurter

CIR BRKR THRM 6A 240VAC 60VDC

9

4230-T120-K0BE-5A

4230-T120-K0BE-5A

E-T-A

CIR BRK THERM-M 5A 480VAC/125VDC

0

4420.0243

4420.0243

Schurter

CIR BRKR THRM MAG 35A 480V 65V

0

IULK11-1REC4-61-1.00-A-01

IULK11-1REC4-61-1.00-A-01

Sensata Technologies – Airpax

CIR BRKR MAG-HYDR 1A LEVER

0

1DU6L

1DU6L

Altech Corporation

CIR BRKR THRM-MAG 6A LEVER

15168

106-M2-P33-0.5A

106-M2-P33-0.5A

E-T-A

CIR BRKR THRM 500MA 250VAC 48VDC

0

Circuit Breakers

1. Overview

Circuit breakers are automatic electrical switches designed to protect circuits from damage caused by overloads or short circuits. Unlike fuses, they can be reset after tripping. Modern circuit breakers ensure electrical safety, prevent equipment damage, and maintain system reliability in residential, commercial, and industrial applications.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
MCB (Miniature Circuit Breaker)Thermal-magnetic protection, <100A ratingResidential wiring, lighting circuits
MCCB (Molded Case Circuit Breaker)Adjustable trip settings, 10-2500A ratingIndustrial machinery, HVAC systems
ACB (Air Circuit Breaker)High fault current interruption, 400-6300A ratingPower distribution in data centers
RCCB (Residual Current Circuit Breaker)Earth leakage protection (5-500mA sensitivity)Outdoor outlets, swimming pool equipment
RCBO (Residual Current Breaker with Overcurrent)Combines overload, short-circuit, and leakage protectionHospital equipment, construction sites

3. Structure and Components

Typical components include: - Enclosure: Flame-retardant insulating material housing - Contacts: Silver alloy for high conductivity - Trip Mechanism: Bimetallic strip (thermal) and electromagnetic coil (magnetic) - Arc Extinguisher: Multi-plate chamber for arc suppression - Operating Lever: Manual ON/OFF control with position indicators

4. Key Technical Parameters

ParameterDescriptionImportance
Rated Current (In)Maximum continuous current without trippingDetermines load capacity
Rated Voltage (Un)Maximum operating voltageEnsures insulation safety
Breaking Capacity (Icu)Maximum fault current interrupting capabilityPrevents catastrophic failure
Tripping CharacteristicsTime-current curve (B/C/D types)Matches load requirements
Pole Number1P to 4P configurationsDetermines phase protection

5. Application Fields

  • Power distribution: Residential panels, commercial switchboards
  • Industrial equipment: Motors, transformers, CNC machines
  • Renewable energy: Solar inverters, wind turbine systems
  • Transportation: EV charging stations, rail traction systems

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Schneider ElectricActi 9 seriesModular design, 0.5-125A range
Siemens5SJ seriesHigh short-circuit withstand, DIN rail mount
ABBEmax seriesSmart connectivity, up to 6300A
General ElectricTHQL seriesUL-certified, industrial motor protection

7. Selection Guidelines

Key considerations: - Match rated current to load requirements (125% safety margin) - Select tripping curve (Type B for resistive loads, C for motors) - Verify breaking capacity against system fault levels - Consider environmental factors (temperature, altitude) - Ensure compliance with standards (IEC 60898, UL 489) - Example: For a 20kW motor (400V), select MCCB with 63A rating, Type C curve, 50kA breaking capacity

8. Industry Trends

Emerging trends include: - Smart grid integration with IoT-enabled monitoring - Compact designs for space-constrained applications - Eco-friendly materials with halogen-free construction - Integration with renewable energy systems - Predictive maintenance via AI-powered diagnostics - Increased adoption of DC circuit breakers for EV infrastructure

RFQ BOM Call Skype Email