Single Conductor Cables (Hook-Up Wire)

Image Part Number Description / PDF Quantity Rfq
39118 003100

39118 003100

Belden

HOOK-UP STRND 18AWG ORANGE 100'

0

83004 008100

83004 008100

Belden

HOOK-UP STRND 24AWG GRAY 100'

11900

8918 001100

8918 001100

Belden

HOOK-UP STRND 18AWG BROWN 100'

27

8013 000100

8013 000100

Belden

WIRE BUS BAR 16AWG NONE 100'

42

83004 003100

83004 003100

Belden

HOOK-UP STRND 24AWG ORANGE 100'

15

8503 004100

8503 004100

Belden

HOOK-UP STRND 22AWG YELLOW 100'

3

8505 0021000

8505 0021000

Belden

HOOK-UP STRND 26AWG RED 1000'

0

8916 009100

8916 009100

Belden

HOOK-UP STRND 14AWG WHITE 100'

12

9918 008100

9918 008100

Belden

HOOK-UP STRND 18AWG GRAY 100'

8

8504 002100

8504 002100

Belden

HOOK-UP STRND 24AWG RED 100'

39

83007 004100

83007 004100

Belden

HOOK-UP STRND 20AWG YELLOW 100'

5200

8527 010100

8527 010100

Belden

HOOK-UP STRND 12AWG BLACK 100'

3

39114 002100

39114 002100

Belden

HOOK-UP STRND 14AWG RED 100'

0

83006 010100

83006 010100

Belden

HOOK-UP STRND 22AWG BLACK 100'

61200

83006 006100

83006 006100

Belden

HOOK-UP STRND 22AWG BLUE 100'

25600

8019 000100

8019 000100

Belden

WIRE BUS BAR 18AWG NONE 100'

30

83006 001100

83006 001100

Belden

HOOK-UP STRND 22AWG BROWN 100'

4900

8899 002U500

8899 002U500

Belden

TEST LEAD 18AWG RED 500'

8

9983 004100

9983 004100

Belden

HOOK-UP STRND 22AWG YELLOW 100'

27

83045 009100

83045 009100

Belden

HOOK-UP STRND 28AWG WHITE 100'

600

Single Conductor Cables (Hook-Up Wire)

1. Overview

Single conductor cables, also known as hook-up wires, are insulated electrical conductors used for low-current signal and power transmission in electronic devices. They serve as fundamental components for internal wiring in PCBs, appliances, and control systems. Their importance lies in enabling reliable electrical connections while maintaining space efficiency and design flexibility in modern electronics.

2. Main Types and Functional Classification

Type Functional Characteristics Application Examples
PVC-Insulated Wire Cost-effective, flexible, 105 C temperature rating Consumer electronics, HVAC systems
Silicone Rubber Insulated Wire High flexibility (-55 C to 200 C), excellent thermal resistance Industrial ovens, medical devices
PTFE/Teflon Insulated Wire Chemical resistance, 200 C operational stability Aerospace sensors, chemical processing equipment
High-Temperature Wire Special polymer jackets for 150-300 C environments Automotive engine compartments, lighting ballasts
Shielded Hook-Up Wire Braided/aluminum foil shielding for EMI protection Telecommunications equipment, measurement instruments

3. Structure and Composition

Typical construction includes:

  • Conductor: Annealed copper (most common), aluminum, or tinned copper (stranded or solid)
  • Insulation: Thermoplastic (PVC, polyethylene), thermoset (silicone rubber), or fluoropolymer materials
  • Shielding: Optional braided copper/aluminum foil layer for EMI protection
  • Jacket: Abrasion-resistant outer layer (PVC, polyurethane) in specific variants

Stranded conductors (e.g., 7/30, 19/34 stranding) optimize flexibility while maintaining conductivity.

4. Key Technical Specifications

Parameter Description Importance
Conductor Gauge (AWG/mm ) Defines current-carrying capacity (e.g., 30 AWG to 10 AWG) Determines power transmission capability
Insulation Thickness 0.1-0.8 mm depending on voltage rating Ensures dielectric strength and safety
Temperature Range -65 C to 300 C operational limits Dictates environmental suitability
Voltage Rating 30V to 1000V depending on insulation material Safety and insulation performance indicator
Bending Life 500-50,000 flex cycles (MIL-W-5088L standard) Crucial for dynamic applications
Shielding Effectiveness 60-100 dB coverage (100 kHz-1 GHz) EMI/RFI interference reduction metric

5. Application Fields

  • Consumer Electronics: PCB interconnects in smartphones, printers, and home appliances
  • Automotive: Sensor wiring, ABS system connections, battery management systems
  • Medical: ECG machine internal wiring, diagnostic equipment signal transmission
  • Industrial: PLC cabinet wiring, robotics joint connections
  • Aerospace: Avionics harnesses, flight control system terminations

6. Leading Manufacturers and Products

Manufacturer Representative Product Key Features
Alpha Wire (Alpha Technologies) EZ-Hook 1385 Series 105 C PVC insulation, UL 1015/CSA Type TEW certification
Lapp Group UNITRONIC LiYY Oil-resistant PVC jacket, 300/500V rating
Panduit Corp. Panfluor 200 Series PTFE-insulated, meets FAA 25.853 flammability requirements
TE Connectivity Raychem Hook-Up Wire Heat-shrinkable insulation, aerospace qualified
Sumitomo Electric Industries AeroElite Series Lightweight composite insulation for aircraft wiring

7. Selection Recommendations

Key considerations:

  • Operating temperature range vs material thermal stability
  • Voltage/current requirements vs conductor cross-section
  • Mechanical stress environment (flexing, vibration)
  • Regulatory certifications (UL, CSA, MIL-SPEC)
  • Chemical exposure resistance (oil, coolant, cleaning agents)
  • EMI sensitivity requiring shielded variants

Example: Automotive engine control units typically require 150 C-rated silicone-insulated wires with vibration-resistant stranded conductors.

8. Industry Trend Analysis

Current development trends include:

  • Miniaturization: 32 AWG+ ultra-fine wires for wearable electronics
  • Material innovation: Halogen-free flame-retardant compounds
  • High-speed capability: Controlled impedance designs for data transmission
  • Automated manufacturing: Laser-marking and precision stripping compatibility
  • Sustainability focus: Recyclable insulation materials and lead-free production

The global hook-up wire market is projected to grow at 5.2% CAGR through 2027, driven by EV and IoT device demand according to MarketsandMarkets research.

RFQ BOM Call Skype Email