Multiple Conductor Cables

Image Part Number Description / PDF Quantity Rfq
W202CLR-100

W202CLR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 20AWG CLR 100'

4

W162BR-25

W162BR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 16AWG BLK/R 25'

28

WMC182FS-100

WMC182FS-100

NTE Electronics, Inc.

CABLE 2COND 18AWG GRY SHD 100'

5

WMC183FS-100

WMC183FS-100

NTE Electronics, Inc.

CABLE 3COND 18AWG GRY SHD 100'

0

W182BR-25

W182BR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 18AWG BLK/R 25'

69

W182CLR-100

W182CLR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 18AWG CLR 100'

1

W142CLR-100

W142CLR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 14AWG CLR 100'

5

W182CLR-25

W182CLR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 18AWG CLR 25'

12

W102BR-100

W102BR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 10AWG B/R 100'

4

W142CLR-25

W142CLR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 14AWG CLR 25'

7

W102CLR-100

W102CLR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 10AWG CLR 100'

3

W162CLR-25

W162CLR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 16AWG CLR 25'

8

W122BR-100

W122BR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 12AWG B/R 100'

4

W122CLR-100

W122CLR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 12AWG CLR 100'

4

WMC222FS-100

WMC222FS-100

NTE Electronics, Inc.

CABLE 2COND 22AWG GRY SHD 100'

4

W102CLR-25

W102CLR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 10AWG CLR 25'

2

W122CLR-25

W122CLR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 12AWG CLR 25'

8

W142BR-100

W142BR-100

NTE Electronics, Inc.

CABLE SPKR 2COND 14AWG B/R 100'

3

W222CLR-25

W222CLR-25

NTE Electronics, Inc.

CABLE SPKR 2COND 22AWG CLR 25'

10

WMC223US-100

WMC223US-100

NTE Electronics, Inc.

CABLE 3COND 22 AWG GRAY 100'

1

Multiple Conductor Cables

1. Overview

Multiple Conductor Cables (MCC) are composite cable structures containing two or more individually insulated conductors enclosed within a common jacket. These cables enable simultaneous transmission of power, data, and control signals in complex systems. Their modular design optimizes space utilization while maintaining signal integrity, making them essential in industrial automation, telecommunications, and energy distribution systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Control CablesLow capacitance, high flexibility, 300-1000V ratingPLC systems, factory automation
Power CablesLarge cross-section conductors, thermal-resistant insulationMachinery power supply, HVAC systems
Data Communication CablesTwisted pair configurations, 100 impedanceEthernet networks, fieldbus systems
Signal CablesShielded designs, noise suppressionSensor networks, instrumentation

3. Structure and Composition

Typical construction includes:

  • Conductors: Annealed copper or aluminum (solid/stranded), 0.14-10mm cross-section
  • Insulation: PVC, XLPE, or FEP materials with 300% elongation
  • Shielding: Aluminum-polyester foil (100% coverage) or braided copper (85% coverage)
  • Jacket: Flame-retardant PVC or LSZH compounds (0.8-3.0mm thickness)

Layered design prevents crosstalk between conductors while maintaining mechanical durability (20N/mm tensile strength).

4. Key Technical Parameters

ParameterTypical RangeSignificance
Conductor Count2-104 conductorsDetermines system integration density
Voltage Rating300V-2000VDefines operational safety margin
Temperature Range-40 C to +125 CEnvironmental adaptability
Shielding Effectiveness60-100dBEMI protection level
Bending Radius7.5 OD to 15 ODInstallation flexibility

5. Application Areas

Primary industries utilizing MCC:

  • Industrial Automation: Robotic arms, CNC machines
  • Transportation: Rail vehicle control systems
  • Energy: Wind turbine pitch control systems
  • Telecommunications: 5G base station interconnects

Case Study: Automotive production lines use 24-conductor control cables to synchronize robotic welding stations with <0.1ms latency.

6. Leading Manufacturers

ManufacturerKey ProductsSpecialization
LegrandOkonite Multi-ConductorBuilding automation solutions
Belden8760 DataTuffIndustrial Ethernet cables
Prysmian GroupFire resistant Ecos ZEnergy sector applications
Alpha Wire3279 UltraFlexHigh-flex robotics cables

7. Selection Guidelines

Key considerations:

  • Current carrying capacity vs. conductor size (I = 3.2 Amm for Cu)
  • Chemical resistance requirements (oil/grease exposure)
  • Signal transmission requirements (CAT5e/CAT6 data rate support)
  • Regulatory compliance (UL/CSA/IEC standards)
  • Mechanical stress factors (vibration, bending cycles)

Recommend conducting thermal cycling tests (-20 C to +85 C) for critical applications.

8. Industry Trends

Emerging developments include:

  • Hybrid cables integrating fiber optics and power conductors
  • Nano-coated conductors for 50% weight reduction
  • Smart cables with embedded temperature/sensor monitoring
  • Halogen-free materials meeting IEC 60754-1 standards
  • Miniaturization trend: 0.08mm micro-conductors in medical cables

Market forecasts indicate 6.2% CAGR through 2030 driven by Industry 4.0 adoption.