Multiple Conductor Cables

Image Part Number Description / PDF Quantity Rfq
MMF006503

MMF006503

VPG Micro-Measurements

326-DFV 1000' WIRE STD. TINNED C

0

MMF006515

MMF006515

VPG Micro-Measurements

330-FTE 500' STD SILVER- PLATED

0

MMF006514

MMF006514

VPG Micro-Measurements

330-FTE 100' STD SILVER- PLATED

0

MMF006517

MMF006517

VPG Micro-Measurements

326-GJF 1000' SOLID NI- CLAD CU

0

MMF006504

MMF006504

VPG Micro-Measurements

330-DFV 100' WIRE STD TINNED CU

0

MMF022881

MMF022881

VPG Micro-Measurements

426-FFT 100' WIRE

0

MMF022879

MMF022879

VPG Micro-Measurements

436-FTT 100' WIRE

0

MMF022575

MMF022575

VPG Micro-Measurements

426-BSV 1000' WIRE

0

MMF006513

MMF006513

VPG Micro-Measurements

336-FTE 50' STD SILVER- PLATED C

0

MMF006520

MMF006520

VPG Micro-Measurements

430-DFV 1000' WIRE STD TINNED CU

0

MMF006521

MMF006521

VPG Micro-Measurements

430-DFV 100' WIRE STD TINNED CU

0

MMF006669

MMF006669

VPG Micro-Measurements

330-DFV 1000' WIRE

0

MMF303337

MMF303337

VPG Micro-Measurements

424-DSV WIRE 500'

0

MMF022880

MMF022880

VPG Micro-Measurements

436-FTT 500' WIRE

0

MMF006508

MMF006508

VPG Micro-Measurements

326-DSV 1000' STD TINNED CU TWIS

0

MMF006510

MMF006510

VPG Micro-Measurements

330-FFE 1000' WIRE STD. SILVER-C

0

MMF006509

MMF006509

VPG Micro-Measurements

330-FFE 100' WIRE STD. SILVER-CL

0

MMF006524

MMF006524

VPG Micro-Measurements

430-FST 100' STD SILVER- PLATE C

0

MMF006506

MMF006506

VPG Micro-Measurements

326-DTV 1000' WIRE STD. TINNED C

0

MMF006512

MMF006512

VPG Micro-Measurements

330-FJT 1000' STD SILVER PLATED

0

Multiple Conductor Cables

1. Overview

Multiple Conductor Cables (MCC) are composite cable structures containing two or more individually insulated conductors enclosed within a common jacket. These cables enable simultaneous transmission of power, data, and control signals in complex systems. Their modular design optimizes space utilization while maintaining signal integrity, making them essential in industrial automation, telecommunications, and energy distribution systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Control CablesLow capacitance, high flexibility, 300-1000V ratingPLC systems, factory automation
Power CablesLarge cross-section conductors, thermal-resistant insulationMachinery power supply, HVAC systems
Data Communication CablesTwisted pair configurations, 100 impedanceEthernet networks, fieldbus systems
Signal CablesShielded designs, noise suppressionSensor networks, instrumentation

3. Structure and Composition

Typical construction includes:

  • Conductors: Annealed copper or aluminum (solid/stranded), 0.14-10mm cross-section
  • Insulation: PVC, XLPE, or FEP materials with 300% elongation
  • Shielding: Aluminum-polyester foil (100% coverage) or braided copper (85% coverage)
  • Jacket: Flame-retardant PVC or LSZH compounds (0.8-3.0mm thickness)

Layered design prevents crosstalk between conductors while maintaining mechanical durability (20N/mm tensile strength).

4. Key Technical Parameters

ParameterTypical RangeSignificance
Conductor Count2-104 conductorsDetermines system integration density
Voltage Rating300V-2000VDefines operational safety margin
Temperature Range-40 C to +125 CEnvironmental adaptability
Shielding Effectiveness60-100dBEMI protection level
Bending Radius7.5 OD to 15 ODInstallation flexibility

5. Application Areas

Primary industries utilizing MCC:

  • Industrial Automation: Robotic arms, CNC machines
  • Transportation: Rail vehicle control systems
  • Energy: Wind turbine pitch control systems
  • Telecommunications: 5G base station interconnects

Case Study: Automotive production lines use 24-conductor control cables to synchronize robotic welding stations with <0.1ms latency.

6. Leading Manufacturers

ManufacturerKey ProductsSpecialization
LegrandOkonite Multi-ConductorBuilding automation solutions
Belden8760 DataTuffIndustrial Ethernet cables
Prysmian GroupFire resistant Ecos ZEnergy sector applications
Alpha Wire3279 UltraFlexHigh-flex robotics cables

7. Selection Guidelines

Key considerations:

  • Current carrying capacity vs. conductor size (I = 3.2 Amm for Cu)
  • Chemical resistance requirements (oil/grease exposure)
  • Signal transmission requirements (CAT5e/CAT6 data rate support)
  • Regulatory compliance (UL/CSA/IEC standards)
  • Mechanical stress factors (vibration, bending cycles)

Recommend conducting thermal cycling tests (-20 C to +85 C) for critical applications.

8. Industry Trends

Emerging developments include:

  • Hybrid cables integrating fiber optics and power conductors
  • Nano-coated conductors for 50% weight reduction
  • Smart cables with embedded temperature/sensor monitoring
  • Halogen-free materials meeting IEC 60754-1 standards
  • Miniaturization trend: 0.08mm micro-conductors in medical cables

Market forecasts indicate 6.2% CAGR through 2030 driven by Industry 4.0 adoption.

RFQ BOM Call Skype Email
Top