Multiple Conductor Cables

Image Part Number Description / PDF Quantity Rfq
44A9676-20-0/2/9-9CS2746

44A9676-20-0/2/9-9CS2746

TE Connectivity Aerospace Defense and Marine

44A9676-20-0/2/9-9CS2746

0

55FA0541-22-FLT4CS2172

55FA0541-22-FLT4CS2172

TE Connectivity Aerospace Defense and Marine

FILTER LINE CABLES

0

55FA0531-14-FLT3CS2172

55FA0531-14-FLT3CS2172

TE Connectivity Aerospace Defense and Marine

55FA0531-14-FLT3CS2172

0

55PC1234-24-3/6/9-9CS3424

55PC1234-24-3/6/9-9CS3424

TE Connectivity Aerospace Defense and Marine

55PC1234-24-3/6/9-9CS3424

0

55FB7122-26-7L/7L6-0

55FB7122-26-7L/7L6-0

TE Connectivity Aerospace Defense and Marine

FILTER LINE CABLES

0

100G1141-1.00-0/2/5/9-0

100G1141-1.00-0/2/5/9-0

TE Connectivity Aerospace Defense and Marine

100G1141-1.00-0/2/5/9-0

0

82A1122-20-6/9-9

82A1122-20-6/9-9

TE Connectivity Aerospace Defense and Marine

82A1122-20-6/9-9

0

44AM1121-24-0/2-9

44AM1121-24-0/2-9

TE Connectivity Aerospace Defense and Marine

44AM1121-24-0/2-9

0

55FB1421-20-FLT2-0CS1925

55FB1421-20-FLT2-0CS1925

TE Connectivity Aerospace Defense and Marine

FILTER LINE CABLES

0

CB4167-000

CB4167-000

TE Connectivity Aerospace Defense and Marine

55/0334-26-9/95/96CS3192

0

44A0121-22-9/936

44A0121-22-9/936

TE Connectivity Aerospace Defense and Marine

44A0121-22-9/936

0

55FB2521-20-FLT2-0CS3347

55FB2521-20-FLT2-0CS3347

TE Connectivity Aerospace Defense and Marine

FILTER LINE CABLES

0

44A9089-16-0/9-9

44A9089-16-0/9-9

TE Connectivity Aerospace Defense and Marine

44A9089-16-0/9-9

0

44AM4121-14-9/96-9CS2275

44AM4121-14-9/96-9CS2275

TE Connectivity Aerospace Defense and Marine

44AM4121-14-9/96-9CS2275

0

44AM1131-24-0/2/9-9

44AM1131-24-0/2/9-9

TE Connectivity Aerospace Defense and Marine

44AM1131-24-0/2/9-9

0

55FB2521-22-FLT2-0CS2858

55FB2521-22-FLT2-0CS2858

TE Connectivity Aerospace Defense and Marine

FILTER LINE CABLES

0

44AC1121-22-9/96-9CS2275

44AC1121-22-9/96-9CS2275

TE Connectivity Aerospace Defense and Marine

44AC1121-22-9/96-9CS2275

0

44A1121-24-6/9-9-MX

44A1121-24-6/9-9-MX

TE Connectivity Aerospace Defense and Marine

44A1121-24-6/9-9

0

44AM1141-18-MSL4-9CS2275

44AM1141-18-MSL4-9CS2275

TE Connectivity Aerospace Defense and Marine

44AM1141-18-MSL4-9CS2275

0

CTC-0012-20-9/5-9CS2340

CTC-0012-20-9/5-9CS2340

TE Connectivity Aerospace Defense and Marine

THERMOCOUPLE CABLE

0

Multiple Conductor Cables

1. Overview

Multiple Conductor Cables (MCC) are composite cable structures containing two or more individually insulated conductors enclosed within a common jacket. These cables enable simultaneous transmission of power, data, and control signals in complex systems. Their modular design optimizes space utilization while maintaining signal integrity, making them essential in industrial automation, telecommunications, and energy distribution systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Control CablesLow capacitance, high flexibility, 300-1000V ratingPLC systems, factory automation
Power CablesLarge cross-section conductors, thermal-resistant insulationMachinery power supply, HVAC systems
Data Communication CablesTwisted pair configurations, 100 impedanceEthernet networks, fieldbus systems
Signal CablesShielded designs, noise suppressionSensor networks, instrumentation

3. Structure and Composition

Typical construction includes:

  • Conductors: Annealed copper or aluminum (solid/stranded), 0.14-10mm cross-section
  • Insulation: PVC, XLPE, or FEP materials with 300% elongation
  • Shielding: Aluminum-polyester foil (100% coverage) or braided copper (85% coverage)
  • Jacket: Flame-retardant PVC or LSZH compounds (0.8-3.0mm thickness)

Layered design prevents crosstalk between conductors while maintaining mechanical durability (20N/mm tensile strength).

4. Key Technical Parameters

ParameterTypical RangeSignificance
Conductor Count2-104 conductorsDetermines system integration density
Voltage Rating300V-2000VDefines operational safety margin
Temperature Range-40 C to +125 CEnvironmental adaptability
Shielding Effectiveness60-100dBEMI protection level
Bending Radius7.5 OD to 15 ODInstallation flexibility

5. Application Areas

Primary industries utilizing MCC:

  • Industrial Automation: Robotic arms, CNC machines
  • Transportation: Rail vehicle control systems
  • Energy: Wind turbine pitch control systems
  • Telecommunications: 5G base station interconnects

Case Study: Automotive production lines use 24-conductor control cables to synchronize robotic welding stations with <0.1ms latency.

6. Leading Manufacturers

ManufacturerKey ProductsSpecialization
LegrandOkonite Multi-ConductorBuilding automation solutions
Belden8760 DataTuffIndustrial Ethernet cables
Prysmian GroupFire resistant Ecos ZEnergy sector applications
Alpha Wire3279 UltraFlexHigh-flex robotics cables

7. Selection Guidelines

Key considerations:

  • Current carrying capacity vs. conductor size (I = 3.2 Amm for Cu)
  • Chemical resistance requirements (oil/grease exposure)
  • Signal transmission requirements (CAT5e/CAT6 data rate support)
  • Regulatory compliance (UL/CSA/IEC standards)
  • Mechanical stress factors (vibration, bending cycles)

Recommend conducting thermal cycling tests (-20 C to +85 C) for critical applications.

8. Industry Trends

Emerging developments include:

  • Hybrid cables integrating fiber optics and power conductors
  • Nano-coated conductors for 50% weight reduction
  • Smart cables with embedded temperature/sensor monitoring
  • Halogen-free materials meeting IEC 60754-1 standards
  • Miniaturization trend: 0.08mm micro-conductors in medical cables

Market forecasts indicate 6.2% CAGR through 2030 driven by Industry 4.0 adoption.

RFQ BOM Call Skype Email
Top