Multiple Conductor Cables

Image Part Number Description / PDF Quantity Rfq
55PC1133-14-9/93/96-9

55PC1133-14-9/93/96-9

TE Connectivity Aerospace Defense and Marine

55PC1133-14-9/93/96-9

0

44AM3121-20-9/96C2275L079

44AM3121-20-9/96C2275L079

TE Connectivity Aerospace Defense and Marine

44AM3121-20-9/96C2275L079

0

CXA-0140-20-6/9-9CS2405

CXA-0140-20-6/9-9CS2405

TE Connectivity Aerospace Defense and Marine

CXA-0140-20-6/9-9CS2405

0

82A0122-20-6/9

82A0122-20-6/9

TE Connectivity Aerospace Defense and Marine

82A0122-20-6/9

0

44AM1121-24-2L/3-0

44AM1121-24-2L/3-0

TE Connectivity Aerospace Defense and Marine

44AM1121-24-2L/3-0

0

44A0121-22-9/928

44A0121-22-9/928

TE Connectivity Aerospace Defense and Marine

44A0121-22-9/928

0

CTC-0057-22-9/5-3

CTC-0057-22-9/5-3

TE Connectivity Aerospace Defense and Marine

THERMOCOUPLE CABLE

0

44A0121-24-0/6CS356

44A0121-24-0/6CS356

TE Connectivity Aerospace Defense and Marine

44A0121-24-0/6CS356

0

55PC0124-16-2/6CS2502

55PC0124-16-2/6CS2502

TE Connectivity Aerospace Defense and Marine

55PC0124-16-2/6CS2502

0

55A6373-28-0/9CS2063

55A6373-28-0/9CS2063

TE Connectivity Aerospace Defense and Marine

55A6373-28-0/9CS2063

0

44A0121-22-9/908

44A0121-22-9/908

TE Connectivity Aerospace Defense and Marine

44A0121-22-9/908

0

55PC2131-16-9/93/96-9

55PC2131-16-9/93/96-9

TE Connectivity Aerospace Defense and Marine

55PC2131-16-9/93/96-9

0

44A0821-18-3/3

44A0821-18-3/3

TE Connectivity Aerospace Defense and Marine

44A0821-18-3/3

0

44A1124-24-2/5-9

44A1124-24-2/5-9

TE Connectivity Aerospace Defense and Marine

44A1124-24-2/5-9

0

44A0121-22-9/958

44A0121-22-9/958

TE Connectivity Aerospace Defense and Marine

44A0121-22-9/958

0

CXA-0140-14-6/9-9CS2405

CXA-0140-14-6/9-9CS2405

TE Connectivity Aerospace Defense and Marine

CXA-0140-14-6/9-9CS2405

0

55/2124-24-2/6-9

55/2124-24-2/6-9

TE Connectivity Aerospace Defense and Marine

55/2124-24-2/6-9

0

44AM1121-16-9/96-9

44AM1121-16-9/96-9

TE Connectivity Aerospace Defense and Marine

44AM1121-16-9/96-9

0

55FB1534-24-FLT3-0CS2173

55FB1534-24-FLT3-0CS2173

TE Connectivity Aerospace Defense and Marine

FILTER LINE CABLES

0

55A4122-14-2/9-9

55A4122-14-2/9-9

TE Connectivity Aerospace Defense and Marine

55A4122-14-2/9-9

0

Multiple Conductor Cables

1. Overview

Multiple Conductor Cables (MCC) are composite cable structures containing two or more individually insulated conductors enclosed within a common jacket. These cables enable simultaneous transmission of power, data, and control signals in complex systems. Their modular design optimizes space utilization while maintaining signal integrity, making them essential in industrial automation, telecommunications, and energy distribution systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Control CablesLow capacitance, high flexibility, 300-1000V ratingPLC systems, factory automation
Power CablesLarge cross-section conductors, thermal-resistant insulationMachinery power supply, HVAC systems
Data Communication CablesTwisted pair configurations, 100 impedanceEthernet networks, fieldbus systems
Signal CablesShielded designs, noise suppressionSensor networks, instrumentation

3. Structure and Composition

Typical construction includes:

  • Conductors: Annealed copper or aluminum (solid/stranded), 0.14-10mm cross-section
  • Insulation: PVC, XLPE, or FEP materials with 300% elongation
  • Shielding: Aluminum-polyester foil (100% coverage) or braided copper (85% coverage)
  • Jacket: Flame-retardant PVC or LSZH compounds (0.8-3.0mm thickness)

Layered design prevents crosstalk between conductors while maintaining mechanical durability (20N/mm tensile strength).

4. Key Technical Parameters

ParameterTypical RangeSignificance
Conductor Count2-104 conductorsDetermines system integration density
Voltage Rating300V-2000VDefines operational safety margin
Temperature Range-40 C to +125 CEnvironmental adaptability
Shielding Effectiveness60-100dBEMI protection level
Bending Radius7.5 OD to 15 ODInstallation flexibility

5. Application Areas

Primary industries utilizing MCC:

  • Industrial Automation: Robotic arms, CNC machines
  • Transportation: Rail vehicle control systems
  • Energy: Wind turbine pitch control systems
  • Telecommunications: 5G base station interconnects

Case Study: Automotive production lines use 24-conductor control cables to synchronize robotic welding stations with <0.1ms latency.

6. Leading Manufacturers

ManufacturerKey ProductsSpecialization
LegrandOkonite Multi-ConductorBuilding automation solutions
Belden8760 DataTuffIndustrial Ethernet cables
Prysmian GroupFire resistant Ecos ZEnergy sector applications
Alpha Wire3279 UltraFlexHigh-flex robotics cables

7. Selection Guidelines

Key considerations:

  • Current carrying capacity vs. conductor size (I = 3.2 Amm for Cu)
  • Chemical resistance requirements (oil/grease exposure)
  • Signal transmission requirements (CAT5e/CAT6 data rate support)
  • Regulatory compliance (UL/CSA/IEC standards)
  • Mechanical stress factors (vibration, bending cycles)

Recommend conducting thermal cycling tests (-20 C to +85 C) for critical applications.

8. Industry Trends

Emerging developments include:

  • Hybrid cables integrating fiber optics and power conductors
  • Nano-coated conductors for 50% weight reduction
  • Smart cables with embedded temperature/sensor monitoring
  • Halogen-free materials meeting IEC 60754-1 standards
  • Miniaturization trend: 0.08mm micro-conductors in medical cables

Market forecasts indicate 6.2% CAGR through 2030 driven by Industry 4.0 adoption.

RFQ BOM Call Skype Email
Top