Multiple Conductor Cables

Image Part Number Description / PDF Quantity Rfq
30-01038

30-01038

Tensility International Corporation

CBL 5CON 18AWG SHLD WHT 153M

0

30-01404

30-01404

Tensility International Corporation

CBL 2COND 20AWG SHLD 153M MPPE

0

31-00081

31-00081

Tensility International Corporation

CBL COIL SHLD 6C 24AWG 1115MM

0

30-00088

30-00088

Tensility International Corporation

CBL 4CON 28AWG SHLD BLK 153M

12

30-00364

30-00364

Tensility International Corporation

CABLE 2COND 26AWG GRAY 305M

14

30-01194

30-01194

Tensility International Corporation

CBL 9CON 32AWG SHLD GRY BIO 153M

0

31-00133

31-00133

Tensility International Corporation

CBL COIL SHLD 9C 22AWG 2230MM

0

30-00397

30-00397

Tensility International Corporation

CABLE 2COND 18AWG CLEAR 305M

3

30-01142

30-01142

Tensility International Corporation

CBL 6CON 28AWG SHLD WHT BIO 153M

0

30-00652

30-00652

Tensility International Corporation

CBL 2CON 32AWG SHLD GRY 305M BIO

0

30-00493

30-00493

Tensility International Corporation

CBL 4CON 24AWG SHLD BLK 153M BIO

14

30-00396

30-00396

Tensility International Corporation

CABLE 2COND 18AWG WHITE 305M

8

30-01422

30-01422

Tensility International Corporation

CBL 3COND 22AWG SHLD 153M MPPE

8

30-01187

30-01187

Tensility International Corporation

CBL 9CON 28AWG SHLD WHT BIO 153M

0

30-00696

30-00696

Tensility International Corporation

CABLE 2COND 26AWG WHITE 305M

7

30-01520

30-01520

Tensility International Corporation

CBL 9COND 24AWG SHLD 153M MPPE

7

31-00151

31-00151

Tensility International Corporation

CBL COIL SHLD 10C 22AWG 2230MM

0

30-01072

30-01072

Tensility International Corporation

CBL 7CON 28AWG SHLD WHT 153M

0

31-00094

31-00094

Tensility International Corporation

CBL COIL SHLD 7C 20AWG 2230MM

0

30-01468

30-01468

Tensility International Corporation

CBL 6COND 20AWG SHLD 153M MPPE

0

Multiple Conductor Cables

1. Overview

Multiple Conductor Cables (MCC) are composite cable structures containing two or more individually insulated conductors enclosed within a common jacket. These cables enable simultaneous transmission of power, data, and control signals in complex systems. Their modular design optimizes space utilization while maintaining signal integrity, making them essential in industrial automation, telecommunications, and energy distribution systems.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Control CablesLow capacitance, high flexibility, 300-1000V ratingPLC systems, factory automation
Power CablesLarge cross-section conductors, thermal-resistant insulationMachinery power supply, HVAC systems
Data Communication CablesTwisted pair configurations, 100 impedanceEthernet networks, fieldbus systems
Signal CablesShielded designs, noise suppressionSensor networks, instrumentation

3. Structure and Composition

Typical construction includes:

  • Conductors: Annealed copper or aluminum (solid/stranded), 0.14-10mm cross-section
  • Insulation: PVC, XLPE, or FEP materials with 300% elongation
  • Shielding: Aluminum-polyester foil (100% coverage) or braided copper (85% coverage)
  • Jacket: Flame-retardant PVC or LSZH compounds (0.8-3.0mm thickness)

Layered design prevents crosstalk between conductors while maintaining mechanical durability (20N/mm tensile strength).

4. Key Technical Parameters

ParameterTypical RangeSignificance
Conductor Count2-104 conductorsDetermines system integration density
Voltage Rating300V-2000VDefines operational safety margin
Temperature Range-40 C to +125 CEnvironmental adaptability
Shielding Effectiveness60-100dBEMI protection level
Bending Radius7.5 OD to 15 ODInstallation flexibility

5. Application Areas

Primary industries utilizing MCC:

  • Industrial Automation: Robotic arms, CNC machines
  • Transportation: Rail vehicle control systems
  • Energy: Wind turbine pitch control systems
  • Telecommunications: 5G base station interconnects

Case Study: Automotive production lines use 24-conductor control cables to synchronize robotic welding stations with <0.1ms latency.

6. Leading Manufacturers

ManufacturerKey ProductsSpecialization
LegrandOkonite Multi-ConductorBuilding automation solutions
Belden8760 DataTuffIndustrial Ethernet cables
Prysmian GroupFire resistant Ecos ZEnergy sector applications
Alpha Wire3279 UltraFlexHigh-flex robotics cables

7. Selection Guidelines

Key considerations:

  • Current carrying capacity vs. conductor size (I = 3.2 Amm for Cu)
  • Chemical resistance requirements (oil/grease exposure)
  • Signal transmission requirements (CAT5e/CAT6 data rate support)
  • Regulatory compliance (UL/CSA/IEC standards)
  • Mechanical stress factors (vibration, bending cycles)

Recommend conducting thermal cycling tests (-20 C to +85 C) for critical applications.

8. Industry Trends

Emerging developments include:

  • Hybrid cables integrating fiber optics and power conductors
  • Nano-coated conductors for 50% weight reduction
  • Smart cables with embedded temperature/sensor monitoring
  • Halogen-free materials meeting IEC 60754-1 standards
  • Miniaturization trend: 0.08mm micro-conductors in medical cables

Market forecasts indicate 6.2% CAGR through 2030 driven by Industry 4.0 adoption.

RFQ BOM Call Skype Email
Top