Wire Ducts, Raceways - Accessories

Image Part Number Description / PDF Quantity Rfq
RF5X3IW-IB-E

RF5X3IW-IB-E

Panduit Corporation

LD5 TO LD3 RACEWAY LOW VOLTAGE R

100

RAFX3IW-X

RAFX3IW-X

Panduit Corporation

FITTING RA FOR RACEWAY3 OFFWHT

330

FRT12X4LBL

FRT12X4LBL

Panduit Corporation

FITTING, HORIZONTAL TEE, 12" X 4

0

CEFXIW-X

CEFXIW-X

Panduit Corporation

CONDUIT ENTRANCE END PWR FITTING

560

ECF10WH-IB-X

ECF10WH-IB-X

Panduit Corporation

LD10 LOW VOLTAGE END CAP FITTING

100

ECFX10EI-X

ECFX10EI-X

Panduit Corporation

CAP END PWR LD/LDP/CD10 IVORY

0

FRVT6X4LBL

FRVT6X4LBL

Panduit Corporation

FITTING, VERTICAL TEE WITH HINGE

20

WGIBRC4EZ

WGIBRC4EZ

Panduit Corporation

WYR-GRID INTERSECTION BEND RADIU

20

OCFX10IG-X

OCFX10IG-X

Panduit Corporation

FITTING OUT COR LD/LDP/CD10 GRY

30

ICFX10EI-X

ICFX10EI-X

Panduit Corporation

FITTING PWR INS CRNR LDP10 IVRY

100

TF10IW-IB-X

TF10IW-IB-X

Panduit Corporation

LD10 LOW VOLTAGE TEE FITTING. IN

100

D4HWH6

D4HWH6

Panduit Corporation

WIRE DUCT WALL DIVIDER PVC 6'

1218

FRVT6X4LYL

FRVT6X4LYL

Panduit Corporation

FITTING, VERTICAL TEE WITH HINGE

0

FREC12X4LBL

FREC12X4LBL

Panduit Corporation

FITTING, END CAP, 12" X 4" (300M

4

ECFX10IG-X

ECFX10IG-X

Panduit Corporation

CAP END PWR LD/LDP/CD10 LGRY

0

ICFX5WH-X

ICFX5WH-X

Panduit Corporation

FITTING PWR INS CRNR LDP5 WHT

0

DJS1WH6

DJS1WH6

Panduit Corporation

DUCT JOINING STRIP WHT X 6'

36

FRFWC6X4LYL

FRFWC6X4LYL

Panduit Corporation

FITTING, 4-WAY CROSS, 6" X 4" (1

132

WRS-A-C10

WRS-A-C10

Panduit Corporation

RETAINER WIRE FOR D/FS ADJ DUCT

0

FRFWC12X4W4BL

FRFWC12X4W4BL

Panduit Corporation

CABLE DUCT 4 WAY CROSS

0

Wire Ducts, Raceways - Accessories

1. Overview

Wire ducts and raceways accessories are essential components in cable management systems, designed to organize, protect, and route electrical wiring in various environments. These accessories include connectors, covers, bends, and mounting hardware that work with primary ducting systems. Their importance lies in enhancing safety, reducing maintenance costs, and ensuring compliance with electrical codes in applications ranging from industrial machinery to data centers.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Cable GlandsSealing and strain relief for cables entering enclosuresIndustrial control panels
Conduit ConnectorsSecure joining of conduit sectionsElectrical distribution systems
Wire Duct CoversProtective covers with snap-in or screw fixationData center cable trays
90 ElbowsDirectional changes for cable routingMachine tool wiring
Cable Ties Mounting BracketsSupport for zip-tie cable organizationAutomotive manufacturing lines

3. Structure and Composition

Typical products feature:

  • Material: Galvanized steel, PVC, or nylon for corrosion resistance
  • Design: Modular interlocking mechanisms for quick assembly
  • Surface Treatment: Zinc plating or powder coating for durability
  • Mounting System: Pre-drilled holes or clip-on interfaces

4. Key Technical Specifications

ParameterDescriptionImportance
Material Temperature Range-20 C to +120 CEnsures performance in extreme conditions
IP RatingIP54 (dust/water resistance)Protection in harsh environments
Load Capacity100-500N/mStructural reliability under cable weight
Fire ResistanceUL94 V-0 ratingCompliance with fire safety standards
Conductor CompatibilityUp to 300mm cablesAccommodates high-power industrial cables

5. Application Fields

Primary industries include:

  • Building Infrastructure: HVAC systems, elevator cabling
  • Telecommunications: Fiber optic cable routing in BTS cabinets
  • Industrial Automation: PLC control cabinet wiring
  • Renewable Energy: Solar inverter connection management
  • Transportation: Rail vehicle cable harnesses

6. Leading Manufacturers

ManufacturerKey ProductsTechnical Advantages
PanduitComNet Ducting SystemsModular design with quick-connect fittings
HellermannTytonFixfox Universal Fixing SystemVibration-resistant automotive connectors
TE ConnectivityRaychem Cable GlandsExplosion-proof sealing solutions
IgusChainflex Cable Carriers2 billion cycle lifespan in robotic arms

7. Selection Guidelines

Key considerations:

  • Environmental Factors: Chemical exposure, UV resistance requirements
  • Cable Specifications: Diameter range, bend radius limitations
  • Installation Constraints: Available mounting space, accessibility
  • Certifications: NEC Article 300 compliance, CE marking
  • Cost Efficiency: Balance between stainless steel vs. polymer options

8. Industry Trends

Emerging developments include:

  • Smart Integration: IoT-enabled raceways with temperature monitoring
  • Material Innovation: Bio-based polymers for sustainability
  • Modular Standardization: Pre-engineered kits for rapid deployment
  • 3D Printing: Custom accessories for complex geometries
  • Electromagnetic Shielding: Integrated EMI protection for data centers