Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
S3X3WH6NM

S3X3WH6NM

Panduit Corporation

WIRE DUCT SLOTTED WHITE 6'

0

FS2X1EI6WRNM

FS2X1EI6WRNM

Panduit Corporation

WIRE DUCT SOLID BASE IVORY 6'

0

NNC37X37IB2

NNC37X37IB2

Panduit Corporation

SLOT DUCT, HALO FR,37MM X 37MM X

0

S4X4YL6

S4X4YL6

Panduit Corporation

WIRE DUCT SOLID BASE RIVET 6'

0

LD3IG10-A

LD3IG10-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE GRY 10'

0

FS1.5X3WH6

FS1.5X3WH6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 6'

0

LDS3IW10-A

LDS3IW10-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 10'

0

FS4X4DG6NM

FS4X4DG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

0

TB170IG8

TB170IG8

Panduit Corporation

WIRE DUCT SOLID BASE SCRW GRY 8'

0

T45BEI2-A

T45BEI2-A

Panduit Corporation

PWR RATED MULTICHAN RACEWAY 2M

0

NE1X2WH6-A

NE1X2WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

TB170IW8

TB170IW8

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 8'

0

G.75X.75BL6

G.75X.75BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

0

S1X1WH6NM-A

S1X1WH6NM-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

T702EI8

T702EI8

Panduit Corporation

TWIN 70 BASE AND COVER TOGETHER

0

FS1X3DG6NM

FS1X3DG6NM

Panduit Corporation

WIRE DUCT SOLID BASE GRAY 6'

0

G2X5WH6-A

G2X5WH6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

S4X4LG6

S4X4LG6

Panduit Corporation

FACEPLATE ACCESSORY

0

DRD22BL6

DRD22BL6

Panduit Corporation

2" PANELMAX DIN WIRING DUCT 6'

0

NS1X1WH6NM

NS1X1WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers