Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G2X4BL6-A

G2X4BL6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

FS3X1WH6NM

FS3X1WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

0

FS1X1EI6WR

FS1X1EI6WR

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 6'

0

OFVR5MT6

OFVR5MT6

Panduit Corporation

SINGLE CHANNEL VERTICAL 6'

0

T702BEI8

T702BEI8

Panduit Corporation

WIRE DUCT SOLID DUAL SCRW IV 8'

0

FS.75X.75WH6-A

FS.75X.75WH6-A

Panduit Corporation

WIRE DUCT SOLID BASE ADH SCRW 6'

0

SC2X2YL2NM

SC2X2YL2NM

Panduit Corporation

FACEPLATE ACCESSORY

0

S1X1WH6NM

S1X1WH6NM

Panduit Corporation

WIRE DUCT SLOTTED WHITE 6'

0

WMBV2

WMBV2

Panduit Corporation

2" (51MM) WIDE VERTICLE WIRE MGM

0

T70BWH2

T70BWH2

Panduit Corporation

WIRE DUCT SOLID BASE SCRW WHT 2'

0

FC3X3IB2

FC3X3IB2

Panduit Corporation

WIRE MANAGEMENT

0

G3X4DG6

G3X4DG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

F2X2LG6N

F2X2LG6N

Panduit Corporation

WIRE MANAGEMENT

0

MC75X50WH2

MC75X50WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

0

T702BWH10

T702BWH10

Panduit Corporation

WIRE DUCT SOLID DUAL SCRW WT 10'

90

G4X3DG6

G4X3DG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

0

G4X2LG6N

G4X2LG6N

Panduit Corporation

WIRE MANAGEMENT

0

F1.5X3LG6N

F1.5X3LG6N

Panduit Corporation

WIRE MANAGEMENT

0

NNC100X75IB2

NNC100X75IB2

Panduit Corporation

SLOT DUCT, HALO FR,100MM X 75MM

0

PDB36-A

PDB36-A

Panduit Corporation

WIRE DUCT SOLID BASE ADH WHT 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email