Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G1X3IB6

G1X3IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

3796

NE1X1.5WH6

NE1X1.5WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

3

D4X4BL6

D4X4BL6

Panduit Corporation

WIRE DUCT ROUND SCREW BLACK 6'

10210

H2X2BL6

H2X2BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

27

D2X2BL6

D2X2BL6

Panduit Corporation

WIRE DUCT ROUND SCREW BLACK 6'

20

D2X3BL6

D2X3BL6

Panduit Corporation

WIRE DUCT ROUND SCREW BLACK 6'

3566

NNC75X75WH2

NNC75X75WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

10130

MC25X62IG2

MC25X62IG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

420

D1X4LG6

D1X4LG6

Panduit Corporation

WIRE DUCT ROUND SCREW GRAY 6'

26

NE1X3WH6

NE1X3WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

24162

LDPH10EI6-A

LDPH10EI6-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 6'

30

MC50X50WH2

MC50X50WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

10320

G2X4LG6-A

G2X4LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

241746

G2X5LG6-A

G2X5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

7

NNC100X100WH2

NNC100X100WH2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

20

G1.5X4IB6

G1.5X4IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

0

D1X3WH6

D1X3WH6

Panduit Corporation

WIRE DUCT ROUND SCREW WHITE 6'

20

PC-662L

PC-662L

Panduit Corporation

7.5X5.25X72.688 MC/CARR 6 FT DUC

0

NNC25X50LG2

NNC25X50LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

0

FS2X1WH6NM

FS2X1WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

126

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers