Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
181-11017

181-11017

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

184-11000

184-11000

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-22033

181-22033

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

181-31003

181-31003

HellermannTyton

SLOTTED WALL WIRING DUCT, 3" X 1

20

181-00603

181-00603

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-00619

181-00619

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

181-32010

181-32010

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

FPL25W-50M

FPL25W-50M

HellermannTyton

HG CORRUGATED CONDUIT WH 50M

0

184-22044

184-22044

HellermannTyton

WIRE DUCT SLOTTED SCREW BLUE 6'

0

181-12010

181-12010

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW GY 6'

0

184-33000

184-33000

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

184-14000

184-14000

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

181-00600

181-00600

HellermannTyton

WIRE DUCT SLOTTED SCREW BLACK 6'

0

184-21006

184-21006

HellermannTyton

SLHD2X1 BLACK PVC DUCT

0

181-24013

181-24013

HellermannTyton

SL2X4 W/ADH GRAY PVC DUCT

0

181-00221

181-00221

HellermannTyton

WIRE DUCT SOLID BASE SCRW GRY 6'

0

181-00179

181-00179

HellermannTyton

WIRE DUCT SLOTTED SCREW ORG 6'

0

181-00665

181-00665

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW WT 6'

0

181-00149

181-00149

HellermannTyton

WIRE DUCT SLOTTED SCREW WHITE 6'

0

181-00211

181-00211

HellermannTyton

WIRE DUCT SLOTTED SCREW BLUE 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email