Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
G2.5X3BL6

G2.5X3BL6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLACK 6'

25

LDPH10WH6-A

LDPH10WH6-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCREW 6'

8

AG8080-BOX

AG8080-BOX

Tecnomatic Corp

WIDE FINGER GRAY DUCT 3 X 3 1

1

1486C72

1486C72

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTENER 6'

0

LDPH5EI10-A

LDPH5EI10-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 10'

200

184-15302

184-15302

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

D2X4BL6

D2X4BL6

Panduit Corporation

WIRE DUCT ROUND SCREW BLACK 6'

12174

181-33005

181-33005

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

181-24001

181-24001

HellermannTyton

WIRE DUCT SOLID BASE SCRW WHT 6'

0

LDPH10WH10-A

LDPH10WH10-A

Panduit Corporation

WIRE DUCT SOLID 2PC ADH SCRW 10'

0

1485C12

1485C12

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 1'

0

1485E36

1485E36

Hammond Manufacturing

WIRE DUCT SOLID 2PC FASTENER 3'

0

LD10IW10-A

LD10IW10-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE WHT 10'

20015200

NE1.5X2WH6

NE1.5X2WH6

Panduit Corporation

WIRE DUCT SLOTTED SCREW WHITE 6'

17

181-00581

181-00581

HellermannTyton

WIRE DUCT SLOTTED ADH SCRW BK 6'

0

3240356

3240356

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

7

F2X3IB6

F2X3IB6

Panduit Corporation

WIRE DUCT SLOTTED SCREW BLUE 6'

9

184-24004

184-24004

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

HS2X2YL6

HS2X2YL6

Panduit Corporation

WIRE DUCT SOLID BASE SCREW 6'

4

F2X5LG6

F2X5LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

29

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers