Wire Ducts, Raceways

Image Part Number Description / PDF Quantity Rfq
F3X3BL6

F3X3BL6

Panduit Corporation

NARROW SLOTTED DUCT, PVC, 3" X 3

9414

LD5EI6-A

LD5EI6-A

Panduit Corporation

WIRE DUCT SOLID ADHESIVE IVRY 6'

14716

3240191

3240191

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

4941275

B40X80S-R

B40X80S-R

Altech Corporation

WIRE DUCT SLOTTED SCREW GRAY 52'

14

3240625

3240625

Phoenix Contact

WIRE DUCT SOLID 2PC RIVET 6.56'

16180

181-15304

181-15304

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

30

D3X3LG6

D3X3LG6

Panduit Corporation

WIRE DUCT ROUND SCREW GRAY 6'

28288

F4X2LG6

F4X2LG6

Panduit Corporation

WIRE DUCT SLOTTED SCREW GRAY 6'

111074

1486B30

1486B30

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 2.5'

0

251-30709

251-30709

HellermannTyton

FT/G GROMMET 3M/RL

0

D1X3BL6

D1X3BL6

Panduit Corporation

WIRE DUCT ROUND SCREW BLACK 6'

96

FS2X2BL6

FS2X2BL6

Panduit Corporation

WIRE DUCT SOLID BASE SCRW BLK 6'

19

FS4X2WH6NM

FS4X2WH6NM

Panduit Corporation

WIRE DUCT SOLID BASE WHITE 6'

5

T45BEI10-A

T45BEI10-A

Panduit Corporation

WIRE DUCT SOLID BASE ADH 10'

0

1486B18

1486B18

Hammond Manufacturing

WIRE DUCT SOLID BASE FASTEN 1.5'

0

TNC50X50LG2

TNC50X50LG2

Panduit Corporation

WIRE DUCT SLOTTED 2PC SCRW 6.56'

10

MCRFW-BS10

MCRFW-BS10

HellermannTyton

WIRE DUCT SOLID MULTI SCREW 10'

0

FS1.5X1.5LG6-A

FS1.5X1.5LG6-A

Panduit Corporation

WIRE DUCT SOLID BASE ADH SCRW 6'

0

F.75X1.5LG6-A

F.75X1.5LG6-A

Panduit Corporation

WIRE DUCT SLOTTED ADH SCRW GY 6'

200768

184-11004

184-11004

HellermannTyton

WIRE DUCT SLOTTED SCREW GRAY 6'

0

Wire Ducts, Raceways

1. Overview

Wire ducts and raceways are structured cable management systems designed to organize, protect, and route electrical and data cables in industrial, commercial, and residential applications. These systems ensure safe and efficient cable routing while complying with electrical codes and standards. Their importance has grown exponentially with the rise of data centers, smart buildings, and industrial automation, where cable density and system reliability are critical.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Enclosed Wire DuctsFull cable encapsulation, dust/water resistance (IP54+), fire-rated materialsData center under-floor routing, HVAC systems
Open-Top RacewaysAccessible design, modular segments, quick cable accessOffice desk power/data integration, machinery control panels
Horizontal Cable ManagersRack-mount design, 1U-4U heights, bend radius controlServer rack cable organization, telecom cabinets
Vertical Raceway SystemsGravity-based cable separation, seismic stabilityMulti-story building backbone cabling, industrial plant installations
Modular Cable TraysInterchangeable components, scalable designFactory automation lines, stadium lighting systems

3. Structure and Components

Typical wire duct/raceway systems consist of: - Base Channels: Extruded aluminum or steel (load-bearing), PVC/ABS polymer (light-duty) - Cover Systems: Snap-on/removable lids with ventilation slots - Connectors: Internal/external corner fittings, tee/junction boxes - Mounting Hardware: Adjustable brackets, adhesive mounts, seismic restraints - Accessories: Cable ties, grounding bars, firestop seals

4. Key Technical Specifications

ParameterImportanceTypical Values
Current Carrying CapacityDetermines maximum safe power load10-200A per duct
Flame RetardancyFire safety complianceUL94 V-0, IEC 60332-1
Material ThicknessMechanical durability0.8-3.2mm (metal), 2-5mm (plastic)
Bend Radius ControlPrevents cable damage25-300mm (varies by cable type)
EMI ShieldingSignal integrity protection60-100dB attenuation

5. Application Areas

  • Data Centers: Server rack cable routing, under-floor/cable tray integration
  • Industrial Automation: PLC cabinet wiring, robotic arm cable protection
  • Commercial Buildings: Office partition raceways, ceiling-mounted AV cable management
  • Transportation: Rail car wiring ducts, airport baggage handling systems
  • Energy: Solar farm DC cable routing, wind turbine internal wiring

6. Leading Manufacturers & Products

ManufacturerKey ProductsTechnical Highlights
PanduitCompuCable RacewaysSeismic-certified, 150% fill capacity
HellermannTytonFixfox Modular DuctsTool-free assembly, IP66 rating
3MScotchflex Industrial RacewaysUV-resistant polymer, -40 C cold bend
SiemensSICAM Cable ManagementIEC 61439-2 compliant, SMART grid integration

7. Selection Recommendations

Key selection criteria: - Environmental factors (temperature range, chemical exposure) - Cable fill ratio (max 75% per NEC 392.22) - Future expansion capacity (minimum 20% spare space) - Installation accessibility (maintenance requirements) - Regulatory compliance (NEC/CE/REACH standards)

8. Industry Trends

Emerging developments include: - Smart raceways with embedded temperature/humidity sensors - Bio-based polymers for sustainable manufacturing (e.g., BASF Ultramid Ccycled ) - AI-driven cable path optimization software integration - Increased adoption of 480V DC cable ducting for hyper-scale data centers

RFQ BOM Call Skype Email