Heat Shrink Tubing

Image Part Number Description / PDF Quantity Rfq
RNF-3000-3/1-0-SP

RNF-3000-3/1-0-SP

TE Connectivity Raychem Cable Protection

HEATSHRNK0.118"X984.3'BLCK METER

0

RHW-34/8-1200/ADH-0

RHW-34/8-1200/ADH-0

TE Connectivity Raychem Cable Protection

HEATSHRINK RHW POLY 34MMX4' BLK

950

DWP-125-3/16-0-STK

DWP-125-3/16-0-STK

TE Connectivity Raychem Cable Protection

HEATSHRINK POLY 3/16"X4' BLK

631

RNF-100-4-CL-STK

RNF-100-4-CL-STK

TE Connectivity Raychem Cable Protection

HEATSHRINK 4" X 4' CLEAR

0

RNF-100-MINI-SPL-3/64-BK

RNF-100-MINI-SPL-3/64-BK

TE Connectivity Raychem Cable Protection

HEATSHRINK RNF-100 3/64"X100'BLK

61

ES1000-NO.2B9X125MMCS7721

ES1000-NO.2B9X125MMCS7721

TE Connectivity Raychem Cable Protection

HEATSHK TUBING 4:1 7.4ID X 125MM

0

X4-1.5-0-SP-SM

X4-1.5-0-SP-SM

TE Connectivity Raychem Cable Protection

HEATSHRNK TUBING 1.5 BLACK 200M

15

VERSAFIT-1/16-0-STK

VERSAFIT-1/16-0-STK

TE Connectivity Raychem Cable Protection

HEATSHRINK 0.073" X 4' BLACK

0

VERSAFIT-3/16-0-SP

VERSAFIT-3/16-0-SP

TE Connectivity Raychem Cable Protection

HEATSHRINK 0.205" X 150M BLACK

41

NTFR-3/16-0SPCS5683

NTFR-3/16-0SPCS5683

TE Connectivity Raychem Cable Protection

HEATSHRINK TUBING 3/16"

0

NTFR-5/8-0-SP-CS5445

NTFR-5/8-0-SP-CS5445

TE Connectivity Raychem Cable Protection

HEATSHRINK TUBING 5/8"

0

ATUM-19/4-0-SP

ATUM-19/4-0-SP

TE Connectivity Raychem Cable Protection

HEATSHRINK DUAL WALL 19MM

0

RT-3-NO.2-0-COIL

RT-3-NO.2-0-COIL

TE Connectivity Raychem Cable Protection

HEATSHRINK 0.319" X 1500' BLACK

0

NTFR-1/2-0SPCS7029

NTFR-1/2-0SPCS7029

TE Connectivity Raychem Cable Protection

HEATSHRINK TUBING 1/2"

0

SCL-1/8-0-STK

SCL-1/8-0-STK

TE Connectivity Raychem Cable Protection

HEATSHRINK 1/8" X 4' BLACK

320

NTFR-1/2-0SPCS7229

NTFR-1/2-0SPCS7229

TE Connectivity Raychem Cable Protection

HEATSHRINK TUBING 1/2"

0

V2-12.0-0-FSP-SM

V2-12.0-0-FSP-SM

TE Connectivity Raychem Cable Protection

HEATSHRINK 1/2" X 164' BLACK

6

ES2000-NO.3-B8-0-75MM

ES2000-NO.3-B8-0-75MM

TE Connectivity Raychem Cable Protection

HEATSHRINK 0.427" X 0.246' BLACK

0

MT1000-3/16-X-STK

MT1000-3/16-X-STK

TE Connectivity Raychem Cable Protection

HEATSHRINK 3/16" X 4' CLEAR

0

RNF-100-4-CL-SP

RNF-100-4-CL-SP

TE Connectivity Raychem Cable Protection

HEAT SHRINK TUBING

0

Heat Shrink Tubing

1. Overview

Heat shrink tubing is a type of polymer material that contracts radially when heated, forming a tight, protective covering over cables, wires, and components. Its ability to provide insulation, mechanical protection, and environmental sealing makes it indispensable in modern electronics, telecommunications, automotive, and aerospace industries.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
PVC Heat ShrinkLow-cost, flexible, good dielectric propertiesConsumer electronics, automotive wiring
Polyolefin TubingHigh abrasion resistance, UV stabilityIndustrial machinery, outdoor cable joints
Fluoropolymer TubingChemical resistance, high-temperature toleranceAerospace hydraulics, semiconductor equipment
Adhesive-Lined TubingSealing against moisture and dustMarine cables, underground sensors
Split Braided TubingEasy installation without disconnecting componentsRetrofit cable protection in robotics

3. Structure and Composition

Typical heat shrink tubing features a three-layer structure:

  • Base Material: Cross-linked polymer (PVC/Polyolefin/PTFE) for mechanical strength
  • Adhesive Layer: Thermoplastic adhesive for sealing (in dual-wall variants)
  • Outer Coating: UV-resistant or flame-retardant additives for environmental protection
The cross-linking process through irradiation or chemical methods enables shape memory functionality.

4. Key Technical Parameters

ParameterSignificanceTypical Range
Shrink TemperatureDetermines activation threshold80-200 C
Shrink RatioIndicates dimensional contraction capability2:1 to 6:1
Operating TemperatureDefines service life limits-55 C to +150 C
Dielectric StrengthMeasures insulation performance15-100kV/mm
Flame RetardancySafety compliance indicatorUL94 V-0/V-2 rated

5. Application Fields

Major industries include:

  • Automotive: Engine compartment wiring harnesses
  • Aerospace: Avionic system insulation
  • Telecommunications: Fiber optic cable splices
  • Medical: Equipment probe cable protection
  • Renewable Energy: Solar panel connector sealing
Case Study: Tesla Model S uses adhesive-lined polyolefin tubing for battery management system wiring.

6. Leading Manufacturers

ManufacturerRepresentative ProductKey Feature
3MHPST-High Performance150 C operating temp, 4:1 ratio
HellermannTytonSecureSeal ADIP68-rated adhesive lining
Sumitomo ElectricFluoroResin FEP200 C with chemical inertness
Alpha WireECO SCLHalogen-free, RoHS compliant

7. Selection Guidelines

Critical factors to consider:

  • Environmental conditions (temperature, chemicals, UV exposure)
  • Mechanical protection requirements
  • Electrical insulation specifications
  • Regulatory certifications (UL/CSA/REACH)
  • Installation method feasibility
Note: For underwater applications, specify adhesive-lined tubing with min. 3mm wall thickness.

8. Industry Trends

Emerging developments include:

  • Nano-coated variants for EMI shielding
  • Bio-based polymers for sustainability
  • Smart tubing with embedded sensors
  • High-expansion ratios (up to 12:1) for complex geometries
  • Low-halogen options meeting stricter fire safety codes
Market growth projected at 6.2% CAGR through 2030, driven by EV and 5G infrastructure demands.

RFQ BOM Call Skype Email