Coaxial Cables (RF)

Image Part Number Description / PDF Quantity Rfq
LMR-200-PVC

LMR-200-PVC

Times Microwave Systems

INDOOR CABLE, BLACK PVC JACKET

0

LMR-600-FR

LMR-600-FR

Times Microwave Systems

CABLE LMR-600 FRPE 500'

2

LMR-400-LLPX

LMR-400-LLPX

Times Microwave Systems

LMR-400 LOW LOSS PLENUM, 500'

3

LMR-195-LLPX

LMR-195-LLPX

Times Microwave Systems

LMR-195 LOW LOSS PLENUM, LISTED

0

LMR-400-FR

LMR-400-FR

Times Microwave Systems

CABLE LMR-400 FRPE 500'

12

LMR-500-UF

LMR-500-UF

Times Microwave Systems

LMR-500 CABLE/STRANDED CENTER CO

0

LMR-200-75

LMR-200-75

Times Microwave Systems

STANDARD CABLE, BLACK PE JACKET

0

LMR-400-DB

LMR-400-DB

Times Microwave Systems

CABLE LMR-400 BLACK PE 500'

9

LMR-300-LLPX

LMR-300-LLPX

Times Microwave Systems

LMR-300 LOW LOSS PLENUM, LISTED

0

LMR-300

LMR-300

Times Microwave Systems

LMR-300 STANDARD CABLE, BLACK PE

2

LMR-200-LLPX

LMR-200-LLPX

Times Microwave Systems

LMR-200 LOW LOSS PLENUM, LISTED

0

LMR-900-LLPX

LMR-900-LLPX

Times Microwave Systems

LMR-900 LOW LOSS PLENUM, LISTED

0

LMR-600-75

LMR-600-75

Times Microwave Systems

STANDARD CABLE, BLACK PE JACKET

0

LMR-400-75

LMR-400-75

Times Microwave Systems

STANDARD CABLE, BLACK PE JACKET

0

LMR-LW240

LMR-LW240

Times Microwave Systems

STANDARD CABLE, ALUMINUM BRAID,

0

LMR-1200-DB

LMR-1200-DB

Times Microwave Systems

LMR-1200 WATERTIGHT, BLACK PE JA

0

LMR-600-DB

LMR-600-DB

Times Microwave Systems

CABLE LMR-600 BLACK PE 500'

11

LMR-400-UF

LMR-400-UF

Times Microwave Systems

CABLE LMR-400 TPE 500'

25

LMR-240-UF-FR

LMR-240-UF-FR

Times Microwave Systems

LMR-240 W/STRANDED CENTER CONDUC

0

LMR-400-UF-FR

LMR-400-UF-FR

Times Microwave Systems

LMR-400 CABLE/STRANDED CENTER CO

0

Coaxial Cables (RF)

1. Overview

RF coaxial cables are cylindrical transmission lines composed of concentric conductors separated by dielectric materials. They enable efficient high-frequency signal transmission (typically above 100 kHz) with excellent noise immunity. These cables serve as critical infrastructure in telecommunications, broadcasting, aerospace, and test measurement systems where signal integrity is paramount.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rigid Coaxial CableMetallic outer conductor, fixed geometryFixed installations in broadcast transmitters
Semi-Rigid CableFormable but not bendable after installationMicrowave ovens, aerospace systems
Flexible Coaxial CableMulti-stranded conductors for bendingTest equipment, mobile communications
Low-Loss Foam DielectricPTFE foam dielectric reduces signal loss5G base stations, satellite links
Triaxial CableDouble shielding for EMI protectionMedical imaging equipment

3. Structure and Composition

Typical construction includes four layers:

  1. Central Conductor: Solid or stranded copper/aluminum for signal transmission
  2. Dielectric Insulator: PTFE, polyethylene, or foam materials maintaining uniform impedance
  3. Shielding Layer: Braided copper/aluminum with foil wrap (85-100% coverage)
  4. Outer Jacket: UV-resistant PVC or plenum-rated materials for environmental protection

4. Key Technical Parameters

ParameterTypical RangeSignificance
Characteristic Impedance50 , 75 standardsMatches system impedance to prevent reflections
Attenuation0.1-10 dB/100ft @1GHzDetermines maximum transmission distance
Frequency RangeDC to 40 GHz (typical)Defines usable bandwidth
VSWR1.1:1 to 2.0:1Measures impedance matching quality
Power Handling500W to 5kW peakLimits maximum operational power

5. Application Fields

  • Telecommunications: 5G infrastructure, fiber-wireless integration
  • Broadcasting: TV/radio transmission lines
  • Military/Aerospace: Radar systems, avionics
  • Test & Measurement: Oscilloscope probes, signal analyzers
  • Industrial IoT: Sensor network backbones

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
CommScopeFSJ1-50ALow-loss foam dielectric, 0-18GHz
AmphenolRG-58UGeneral-purpose 50 cable
Times MicrowaveLMR-400Weather-resistant, 0-6GHz
Huber+SuhnerRFS1000Heliax rigid line for base stations
HuaweiRF-355G massive MIMO solution

7. Selection Guidelines

Key considerations:

  • Frequency Requirements: Match cable's usable range with system operating frequency
  • Environmental Conditions: Outdoor cables require UV protection and temperature resistance (-40 C to +85 C)
  • Bending Radius: Minimum bend radius specification (typically 10 cable diameter)
  • Connectivity: Ensure compatibility with connectors (N-type, SMA, BNC)
  • Cost vs Performance: Balance loss characteristics against budget constraints

8. Industry Trends

Current development directions include:

  • High-Frequency Optimization: Supporting 6G terahertz band exploration
  • Nanodielectric Materials: Graphene-enhanced insulation for lower loss
  • Miniaturization: 0.8mm outer diameter cables for wearable devices
  • Smart Cables: Integrated sensors for real-time condition monitoring
  • Environmental Compliance: Halogen-free flame retardant (HFFR) jacket materials
RFQ BOM Call Skype Email
Top