Coaxial Cables (RF)

Image Part Number Description / PDF Quantity Rfq
7522B0331-0

7522B0331-0

TE Connectivity Raychem Cable Protection

COAX CABLE-TWINAXIAL

0

CF2197-000

CF2197-000

TE Connectivity Raychem Cable Protection

CABLE TRIAXIAL 26AWG 2500'

0

10605-22-96

10605-22-96

TE Connectivity Raychem Cable Protection

COAX CABLE-DATA BUS

0

7528F5614-9CS2358

7528F5614-9CS2358

TE Connectivity Raychem Cable Protection

COAX CABLE-STANDARD P

0

7724D3664-9CS2187

7724D3664-9CS2187

TE Connectivity Raychem Cable Protection

COAX CABLE-DATA BUS

0

7724S8664-9

7724S8664-9

TE Connectivity Raychem Cable Protection

COAX CABLE-DATA BUS

0

5030A1314-0

5030A1314-0

TE Connectivity Raychem Cable Protection

COAX CABLE-STANDARD P

0

10612-24-9-L013

10612-24-9-L013

TE Connectivity Raychem Cable Protection

COAX CABLE-DATA BUS

0

4126S5664-0CS3129

4126S5664-0CS3129

TE Connectivity Raychem Cable Protection

COAX CABLE-STANDARD P

0

2526E1114-9

2526E1114-9

TE Connectivity Raychem Cable Protection

COAX CABLE-TWINAXIAL

0

2022E0421-0

2022E0421-0

TE Connectivity Raychem Cable Protection

COAX CABLE-HIGH PERFO

0

2020H3422-9

2020H3422-9

TE Connectivity Raychem Cable Protection

COAX CABLE-HIGH PERFO

0

7520A1311-0

7520A1311-0

TE Connectivity Raychem Cable Protection

CABLE COAXIAL 20AWG 2500'

0

5020A1311-0

5020A1311-0

TE Connectivity Raychem Cable Protection

CABLE COAXIAL 20AWG 2500'

0

7526A1317-0

7526A1317-0

TE Connectivity Raychem Cable Protection

COAX CABLE-STANDARD P

0

7518A5611-0

7518A5611-0

TE Connectivity Raychem Cable Protection

COAX CABLE-STANDARD P

0

5020A1611-9

5020A1611-9

TE Connectivity Raychem Cable Protection

COAX CABLE-STANDARD P

0

2424A3631-6CS3338

2424A3631-6CS3338

TE Connectivity Raychem Cable Protection

COAX CABLE-TWINAXIAL

0

7524E5312-0

7524E5312-0

TE Connectivity Raychem Cable Protection

COAX CABLE-STANDARD P

0

2024D0114-9

2024D0114-9

TE Connectivity Raychem Cable Protection

COAX CABLE-TWINAXIAL

0

Coaxial Cables (RF)

1. Overview

RF coaxial cables are cylindrical transmission lines composed of concentric conductors separated by dielectric materials. They enable efficient high-frequency signal transmission (typically above 100 kHz) with excellent noise immunity. These cables serve as critical infrastructure in telecommunications, broadcasting, aerospace, and test measurement systems where signal integrity is paramount.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rigid Coaxial CableMetallic outer conductor, fixed geometryFixed installations in broadcast transmitters
Semi-Rigid CableFormable but not bendable after installationMicrowave ovens, aerospace systems
Flexible Coaxial CableMulti-stranded conductors for bendingTest equipment, mobile communications
Low-Loss Foam DielectricPTFE foam dielectric reduces signal loss5G base stations, satellite links
Triaxial CableDouble shielding for EMI protectionMedical imaging equipment

3. Structure and Composition

Typical construction includes four layers:

  1. Central Conductor: Solid or stranded copper/aluminum for signal transmission
  2. Dielectric Insulator: PTFE, polyethylene, or foam materials maintaining uniform impedance
  3. Shielding Layer: Braided copper/aluminum with foil wrap (85-100% coverage)
  4. Outer Jacket: UV-resistant PVC or plenum-rated materials for environmental protection

4. Key Technical Parameters

ParameterTypical RangeSignificance
Characteristic Impedance50 , 75 standardsMatches system impedance to prevent reflections
Attenuation0.1-10 dB/100ft @1GHzDetermines maximum transmission distance
Frequency RangeDC to 40 GHz (typical)Defines usable bandwidth
VSWR1.1:1 to 2.0:1Measures impedance matching quality
Power Handling500W to 5kW peakLimits maximum operational power

5. Application Fields

  • Telecommunications: 5G infrastructure, fiber-wireless integration
  • Broadcasting: TV/radio transmission lines
  • Military/Aerospace: Radar systems, avionics
  • Test & Measurement: Oscilloscope probes, signal analyzers
  • Industrial IoT: Sensor network backbones

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
CommScopeFSJ1-50ALow-loss foam dielectric, 0-18GHz
AmphenolRG-58UGeneral-purpose 50 cable
Times MicrowaveLMR-400Weather-resistant, 0-6GHz
Huber+SuhnerRFS1000Heliax rigid line for base stations
HuaweiRF-355G massive MIMO solution

7. Selection Guidelines

Key considerations:

  • Frequency Requirements: Match cable's usable range with system operating frequency
  • Environmental Conditions: Outdoor cables require UV protection and temperature resistance (-40 C to +85 C)
  • Bending Radius: Minimum bend radius specification (typically 10 cable diameter)
  • Connectivity: Ensure compatibility with connectors (N-type, SMA, BNC)
  • Cost vs Performance: Balance loss characteristics against budget constraints

8. Industry Trends

Current development directions include:

  • High-Frequency Optimization: Supporting 6G terahertz band exploration
  • Nanodielectric Materials: Graphene-enhanced insulation for lower loss
  • Miniaturization: 0.8mm outer diameter cables for wearable devices
  • Smart Cables: Integrated sensors for real-time condition monitoring
  • Environmental Compliance: Halogen-free flame retardant (HFFR) jacket materials
RFQ BOM Call Skype Email
Top