Specialized Cable Assemblies

Image Part Number Description / PDF Quantity Rfq
2829724-2

2829724-2

TE Connectivity AMP Connectors

CABLE ASSEMBLY, GROUND CLIP 6 IN

9431

2323858-1

2323858-1

TE Connectivity AMP Connectors

CA, 25A TRIBUTARY GENERICAL

20

2274955-1

2274955-1

TE Connectivity AMP Connectors

CABLE ASSEMBLY STRADA

0

2323857-1

2323857-1

TE Connectivity AMP Connectors

CA, 50A TRIBUTARY GENERICAL

78

2213759-3

2213759-3

TE Connectivity AMP Connectors

JUMPER ASSEMBLY PV4S 1.5KV 500MM

430

2829724-1

2829724-1

TE Connectivity AMP Connectors

CABLE ASSEMBLY, GROUND CLIP 4 IN

3381

2213759-1

2213759-1

TE Connectivity AMP Connectors

JUMPER ASSEMBLY PV4S 1.5KV 300MM

435

2311291-1

2311291-1

TE Connectivity AMP Connectors

CA, BUSBAR MATING TO CORD END TM

386

2213759-8

2213759-8

TE Connectivity AMP Connectors

JUMPER ASSEMBLY PV4S 1.5KV 1M

421

2337275-1

2337275-1

TE Connectivity AMP Connectors

SIDE EXIT CROWN CLIP JR CBLE ASS

0

1-2213759-3

1-2213759-3

TE Connectivity AMP Connectors

JUMPER ASSEMBLY PV4S, 1KV, 500MM

0

1958023-1

1958023-1

TE Connectivity AMP Connectors

4/0 BRAIDED CABLE ASSEMBLY

0

1-2213759-8

1-2213759-8

TE Connectivity AMP Connectors

JUMPER ASSEMBLY PV4S, 1KV, 1M

0

2159562-1

2159562-1

TE Connectivity AMP Connectors

CABLE ASSY, PRESS FIT POWER,FB.

0

2159443-1

2159443-1

TE Connectivity AMP Connectors

CABLE ASSY,SLED POWER,FB.

40

1337707-1

1337707-1

TE Connectivity AMP Connectors

25MM CSA BRAID M8 - M8 250MM

0

2-556127-0

2-556127-0

TE Connectivity AMP Connectors

CABLE ASSY PWR-PWR 8 WIRE 56"

0

1-556127-3

1-556127-3

TE Connectivity AMP Connectors

CABLE ASSY PWR-PWR 8 WIRE 128"

0

2106725-3

2106725-3

TE Connectivity AMP Connectors

CABLE ASSY POWER FEED 15FT

0

2-556127-9

2-556127-9

TE Connectivity AMP Connectors

CABLE ASSY PWR-PWR 8 WIRE 28"

0

Specialized Cable Assemblies

1. Overview

Specialized Cable Assemblies are engineered interconnect solutions designed for specific performance requirements in demanding environments. These assemblies combine multiple cables, connectors, and shielding components into customized configurations to ensure reliable signal transmission, power delivery, or data integrity. Their importance spans across industries requiring precision, durability, and compliance with stringent standards, such as aerospace, medical, and industrial automation sectors.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
High-Temperature CablesRated for continuous operation above 150 C, using materials like PTFE or silicone rubberAerospace engine sensors, industrial ovens
EMI-Shielded AssembliesMulti-layer shielding (braided copper, foil) to block electromagnetic interferenceMilitary communication systems, MRI machines
Flexible Robotic CablesHigh-flex materials with torsion resistance for dynamic motion applicationsIndustrial robots, automated guided vehicles
High-Speed Data CablesControlled impedance (100-150 ) for signal integrity up to 40GbpsData centers, 5G base stations
Submersible CablesHermetically sealed connectors and waterproof jackets for underwater deploymentOffshore oil rigs, underwater drones

3. Structure and Components

A typical specialized cable assembly consists of:

  • Conductors: Annealed copper or aluminum with plating (tin, silver) for conductivity
  • Insulation: Materials like XLPE, FEP, or TPU based on temperature/dielectric needs
  • Shielding: Combination of braided copper, aluminum mylar tape, and drain wires
  • Jacket: Abrasion-resistant thermoplastic elastomers (TPE) or halogen-free compounds
  • Connectors: Custom-molded interfaces with locking mechanisms (e.g., MIL-DTL-38999, USB 3.1)

4. Key Technical Specifications

ParameterImportance
Conductor MaterialDetermines conductivity (60-100% IACS) and corrosion resistance
Insulation ResistanceMust exceed 100M to prevent leakage currents
Operating TemperatureDefines functional range (-65 C to +250 C typical)
Voltage RatingSafety margin for dielectric breakdown prevention
Bend RadiusMinimum curvature to avoid mechanical failure (3 OD standard)
Insertion LossCritical for high-frequency signal integrity ( 0.5dB@10GHz)

5. Application Fields

  • Aerospace: Flight control systems, avionics, and satellite communication
  • Medical: Diagnostic imaging equipment (CT/MRI), surgical robots
  • Automotive: EV battery management systems, ADAS sensors
  • Energy: Wind turbine pitch control, oil rig monitoring systems

Case Study: A subsea oil exploration project utilized 10km-length specialized assemblies with polyurethane jackets, achieving 10-year deployment without degradation at 3000m depth.

6. Leading Manufacturers and Products

ManufacturerRepresentative Product
Amphenol IndustrialMaxGuard High-Temp Cable (200 C rating)
TE ConnectivityMATE-AXAL High-Speed Automotive Cable
SamtecQSH-DP High-Density Flex Assembly
LEONI AGROBUSTEC Robotic Cable Series

7. Selection Guidelines

Key considerations include:

  • Environmental factors (temperature, chemicals, mechanical stress)
  • Signal/power requirements (frequency, voltage, current capacity)
  • Regulatory certifications (UL, RoHS, MIL-STD)
  • Cost vs. longevity trade-offs for high-reliability applications

8. Industry Trends

Emerging developments include:

  • Adoption of hybrid cables integrating fiber optics and power conductors
  • Nanocoatings for enhanced EMI protection and corrosion resistance
  • AI-driven predictive maintenance through embedded sensor cables
  • Increased demand for halogen-free materials meeting IEC 62591 standards
RFQ BOM Call Skype Email
Top