Specialized Cable Assemblies

Image Part Number Description / PDF Quantity Rfq
20886110100

20886110100

HARTING

SYPCEMKAB.HAN-BRID/CU KU.PCI+BU

3

20826011110

20826011110

HARTING

HA-VIS PRELINK CABLE ASSEMBLY, C

0

09457251332

09457251332

HARTING

RJI KABEL IP67 HYBRID FLEX 25M

0

33572110055001

33572110055001

HARTING

HYBR.CABLE ASSY,AC,5M,FO+POW-MM-

0

33572110050002

33572110050002

HARTING

HYBR.CABLE ASSY, DC, 5M -2 X HAN

0

20826002006

20826002006

HARTING

2X PRELINK CORD 4X2XAWG27/7 CAT.

0

09457251545

09457251545

HARTING

RJI CABLE8AWG28/7HYBOUT IP67ME

0

33572110010002

33572110010002

HARTING

HYBR.CABLE ASSY, DC, 1M -2X HAN3

0

20826001008

20826001008

HARTING

1X PRELINK CORD 4X2XAWG27/7 CAT.

0

20826002040

20826002040

HARTING

2X PRELINK CORD 4X2XAWG27/7 CAT.

0

20888410015

20888410015

HARTING

SYPCEMKAB.PS HAN-Q8/0 KU.PCI+BU

0

33571110015002

33571110015002

HARTING

HYBR.CABLE ASSY,DC,1M,FO+POW-MM-

0

20888410050

20888410050

HARTING

SYPCEMKAB.PS HAN-Q8/0 KU.PCI+BU

0

33574110605006

33574110605006

HARTING

H.CA.AS-1XHAN3A-60M-AC-D;SM;1XLC

0

09457251504

09457251504

HARTING

RJI CORDIP67 HYBR CAT6 2XHAN3A

0

20886110015

20886110015

HARTING

SYPCEM CABLE HAN-BRID/CU THERMOP

0

20886411015

20886411015

HARTING

SYPCEMKAB.HAN-Q4/2 PCI+BU 5X4QMM

0

33572110150004

33572110150004

HARTING

HYBR.CABLE ASSY, AC, 15M -2 X HA

0

20826002020

20826002020

HARTING

2X PRELINK CORD 4X2XAWG27/7 CAT.

0

09457251503

09457251503

HARTING

HAN 3A PLASTIC RJ45 HYBRID CABLE

0

Specialized Cable Assemblies

1. Overview

Specialized Cable Assemblies are engineered interconnect solutions designed for specific performance requirements in demanding environments. These assemblies combine multiple cables, connectors, and shielding components into customized configurations to ensure reliable signal transmission, power delivery, or data integrity. Their importance spans across industries requiring precision, durability, and compliance with stringent standards, such as aerospace, medical, and industrial automation sectors.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
High-Temperature CablesRated for continuous operation above 150 C, using materials like PTFE or silicone rubberAerospace engine sensors, industrial ovens
EMI-Shielded AssembliesMulti-layer shielding (braided copper, foil) to block electromagnetic interferenceMilitary communication systems, MRI machines
Flexible Robotic CablesHigh-flex materials with torsion resistance for dynamic motion applicationsIndustrial robots, automated guided vehicles
High-Speed Data CablesControlled impedance (100-150 ) for signal integrity up to 40GbpsData centers, 5G base stations
Submersible CablesHermetically sealed connectors and waterproof jackets for underwater deploymentOffshore oil rigs, underwater drones

3. Structure and Components

A typical specialized cable assembly consists of:

  • Conductors: Annealed copper or aluminum with plating (tin, silver) for conductivity
  • Insulation: Materials like XLPE, FEP, or TPU based on temperature/dielectric needs
  • Shielding: Combination of braided copper, aluminum mylar tape, and drain wires
  • Jacket: Abrasion-resistant thermoplastic elastomers (TPE) or halogen-free compounds
  • Connectors: Custom-molded interfaces with locking mechanisms (e.g., MIL-DTL-38999, USB 3.1)

4. Key Technical Specifications

ParameterImportance
Conductor MaterialDetermines conductivity (60-100% IACS) and corrosion resistance
Insulation ResistanceMust exceed 100M to prevent leakage currents
Operating TemperatureDefines functional range (-65 C to +250 C typical)
Voltage RatingSafety margin for dielectric breakdown prevention
Bend RadiusMinimum curvature to avoid mechanical failure (3 OD standard)
Insertion LossCritical for high-frequency signal integrity ( 0.5dB@10GHz)

5. Application Fields

  • Aerospace: Flight control systems, avionics, and satellite communication
  • Medical: Diagnostic imaging equipment (CT/MRI), surgical robots
  • Automotive: EV battery management systems, ADAS sensors
  • Energy: Wind turbine pitch control, oil rig monitoring systems

Case Study: A subsea oil exploration project utilized 10km-length specialized assemblies with polyurethane jackets, achieving 10-year deployment without degradation at 3000m depth.

6. Leading Manufacturers and Products

ManufacturerRepresentative Product
Amphenol IndustrialMaxGuard High-Temp Cable (200 C rating)
TE ConnectivityMATE-AXAL High-Speed Automotive Cable
SamtecQSH-DP High-Density Flex Assembly
LEONI AGROBUSTEC Robotic Cable Series

7. Selection Guidelines

Key considerations include:

  • Environmental factors (temperature, chemicals, mechanical stress)
  • Signal/power requirements (frequency, voltage, current capacity)
  • Regulatory certifications (UL, RoHS, MIL-STD)
  • Cost vs. longevity trade-offs for high-reliability applications

8. Industry Trends

Emerging developments include:

  • Adoption of hybrid cables integrating fiber optics and power conductors
  • Nanocoatings for enhanced EMI protection and corrosion resistance
  • AI-driven predictive maintenance through embedded sensor cables
  • Increased demand for halogen-free materials meeting IEC 62591 standards
RFQ BOM Call Skype Email
Top