Coaxial Cables (RF)

Image Part Number Description / PDF Quantity Rfq
CA-DKCA1-152L3-DPDRP-12

CA-DKCA1-152L3-DPDRP-12

Adam Tech

MCX TO MCX RF FOR RG178 CABLE AS

106

CA-DKCA0-305L1-ALI0-O

CA-DKCA0-305L1-ALI0-O

Adam Tech

WATERPROOF SMA TO IPEX FOR 1.37

142

CA-DKCA0-152L1-ALI0-O

CA-DKCA0-152L1-ALI0-O

Adam Tech

CBL ASSY RP-SMA TO IPEX SKT-PLUG

190

CA-DKCA1-152L0-I0-6

CA-DKCA1-152L0-I0-6

Adam Tech

IPEX FOR 1.13 CABLE ASS'Y 6"(152

0

CA-DKCA1-305L1-ALI0

CA-DKCA1-305L1-ALI0

Adam Tech

SMA TO IPEX FOR 1.37 CABLEASS'Y

356

CA-DKCA1-152L0-AJI5

CA-DKCA1-152L0-AJI5

Adam Tech

SMA TO IPEX-4(IV)RF FOR 1.13 CBL

0

CA-DKCA1-152L5-EPR-HSBL-12

CA-DKCA1-152L5-EPR-HSBL-12

Adam Tech

MMCX RF FOR RG316 CABLE ASS'Y 12

101

CA-DKCA1-152L5-APAJ

CA-DKCA1-152L5-APAJ

Adam Tech

SMA TO SMA FOR RG316 CABLE ASS'Y

312

CA-DKCA1-305LQ-ALI5

CA-DKCA1-305LQ-ALI5

Adam Tech

SMA TO IPEX FOR 0.81 CABLE A

0

CA-DKCA0-305L0-AJI0-O

CA-DKCA0-305L0-AJI0-O

Adam Tech

WATERPROOF SMA TO IPEX FOR 1.13

144

CA-DKCA1-305L0-AJI0

CA-DKCA1-305L0-AJI0

Adam Tech

SMA TO IPEX RF FOR 1.13CABLE ASS

270

CA-DKCA1-305L5-APAJ

CA-DKCA1-305L5-APAJ

Adam Tech

SMA TO SMA FOR RG316 CABLE ASS'Y

115

CA-DKCA1-152L0-I0-12

CA-DKCA1-152L0-I0-12

Adam Tech

IPEX FOR 1.13 CABLE ASS'Y 12"(30

0

CA-DKCA1-153L3-EPEP

CA-DKCA1-153L3-EPEP

Adam Tech

CABLE ASSEMBLY MMXC - MMXC 6"

0

CA-BNC-P-P-01-1800L

CA-BNC-P-P-01-1800L

Adam Tech

CABLE ASSEMBLY BNC-BNC 70"

0

CA-DKCA1-200L1-I0I0

CA-DKCA1-200L1-I0I0

Adam Tech

CABLE ASSEMBLY I-PEX/I-PEX 8"

0

CA-BNC-P-P-01-915L

CA-BNC-P-P-01-915L

Adam Tech

CABLE ASSEMBLY BNC-BNC 36"

0

CA-BNC-P-P-02-610L

CA-BNC-P-P-02-610L

Adam Tech

CABLE ASSEMBLY BNC-BNC 24"

0

CA-DKCA1-220LQ-I0I0

CA-DKCA1-220LQ-I0I0

Adam Tech

CABLE ASSEMBLY I-PEX/I-PEX 8.6"

0

CA-DKCA0-152L0-AJI0-O

CA-DKCA0-152L0-AJI0-O

Adam Tech

WATERPROOF SMA TO IPEX FOR 1.13

0

Coaxial Cables (RF)

1. Overview

RF coaxial cables are cylindrical transmission lines consisting of concentric conductors separated by dielectric materials. They enable efficient transfer of high-frequency electrical signals (typically 1 MHz to 110 GHz) with minimal interference, making them critical components in telecommunications, broadcasting, aerospace, and test equipment. Their shielded structure ensures signal integrity in noisy environments.

2. Main Types and Functional Classification

TypeKey FeaturesApplications
Rigid Coaxial CableMetallic outer conductor, fixed geometryTest labs, high-power transmitters
Semi-Rigid CableFormable but non-flexing, excellent shieldingMicrowave systems, aerospace
Flexible Coaxial CableBraided shield, bendableGeneral-purpose communication systems
Low-Loss Foam DielectricPE/PTFE dielectric, reduced attenuation5G infrastructure, satellite links

3. Structure and Composition

Typical construction includes:
  1. Center Conductor: Solid/stranded copper/aluminum for signal transmission
  2. Dielectric Insulator: Polyethylene (PE) or PTFE foam maintaining uniform impedance
  3. Shielding Layer: Braided copper/aluminum with 85-95% coverage (single/double layers)
  4. Outer Jacket: PVC/PE for mechanical/environmental protection
Critical dimensions determine characteristic impedance (commonly 50 for data/75 for video).

4. Key Technical Parameters

ParameterDescriptionImportance
Characteristic ImpedanceMatched load resistance (50/75 )Minimizes signal reflection
Attenuation (dB/100m)Signal loss per unit lengthDetermines transmission distance
Frequency RangeOperational bandwidth (e.g., 0-18GHz)Limits application scope
VSWRVoltage Standing Wave RatioMeasures impedance matching quality
Power HandlingMax RF power capacityPrevents dielectric breakdown

5. Application Fields

  • Telecommunications: 5G base stations, fiber-wireless systems
  • Broadcasting: TV antenna feeds, studio equipment
  • Aerospace: Radar systems, avionics
  • Test & Measurement: Oscilloscope probes, signal analyzers
  • Industrial IoT: Wireless sensor networks

6. Leading Manufacturers

ManufacturerKey Products
Amphenol CorporationSUCOFLEX 104, 106 series
TE ConnectivityRadiation-resistant RG-58
HUBER+SUHNERRF flexible cables (SST series)
CommScopeHeliax FSJ1-50A
Southwest Microwave832 Series semi-rigid

7. Selection Guidelines

Key considerations:
  • Match impedance to system requirements
  • Verify frequency/attenuation specifications
  • Environmental factors (temperature, UV resistance)
  • Mechanical requirements (flexure life, bending radius)
  • Connector compatibility (SMA, N-Type, etc.)
Example: 5G massive MIMO deployment requires low-PIM (Passive Intermodulation) cables with <0.1dB/100m loss at 3.5GHz.

8. Industry Trends

  • High-Frequency Demand: Development of 110GHz+ cables for 6G research
  • Weight Reduction: Composite materials in aerospace applications
  • Green Manufacturing: Halogen-free jacket materials adoption
  • Smart Cables: Embedded sensors for condition monitoring
  • Standardization: 5G NR band-specific cable specifications
RFQ BOM Call Skype Email