Patchbay, Jack Panels

Image Part Number Description / PDF Quantity Rfq
MMVP48K2NT

MMVP48K2NT

Switchcraft / Conxall

1.5RU, NORMALLED, NON-TERMINATED

2

TT96EDACNOX

TT96EDACNOX

Switchcraft / Conxall

JACK EDAC 120PIN BROUGHT OUT

0

PT16FX16M

PT16FX16M

Switchcraft / Conxall

16 FEMALE XLR TO 16 MALE XLR

1

VPP26K1HD75TX

VPP26K1HD75TX

Switchcraft / Conxall

PATCHBAY 26JACK HD TERMINATED

2

MMVPSMB48K1UHD

MMVPSMB48K1UHD

Switchcraft / Conxall

ULTRA VIDEOPATCH PANEL UHD 1 RAC

0

QGPK3B440

QGPK3B440

Switchcraft / Conxall

CONN PATCHBAY 3.5" BLANK PANEL

16

PT16MX2DB25

PT16MX2DB25

Switchcraft / Conxall

I/O PANEL 1RU 16 M

3

9625

9625

Switchcraft / Conxall

STUDIOPATCH 96 PTS W

2

MVP32K2NTX

MVP32K2NTX

Switchcraft / Conxall

1.5RU, NORMALLED, NON-TERMINATED

2

MMVPD48K1NNT

MMVPD48K1NNT

Switchcraft / Conxall

1RU, 2X48 MICROSIZE 12G 4K/8K VI

0

MMVPMB48K1NNT

MMVPMB48K1NNT

Switchcraft / Conxall

1RU, 2X48 MICROSIZE 12G 4K/8K VI

0

MT48FNX

MT48FNX

Switchcraft / Conxall

CONN PATCHBAY 48JACKS 1.75"

13

TTPFA96K1NOX

TTPFA96K1NOX

Switchcraft / Conxall

PATCHBAY 96TT JACK 1.75" WIRED

0

TTPFA96K1NSX

TTPFA96K1NSX

Switchcraft / Conxall

PATCHBAY 96TT JACK 1.75" WIRED

0

MMVPB32K1NNT

MMVPB32K1NNT

Switchcraft / Conxall

1RU, 2X32 MIDSIZE 12G 4K/8K VIDE

0

PT8FX8MX2DB25

PT8FX8MX2DB25

Switchcraft / Conxall

I/O PANEL 1RU 8F 8

3

TTP96ASFNX

TTP96ASFNX

Switchcraft / Conxall

CONN PATCHBAY 96TT JACKS FULL

0

VPP24K3HD75TX

VPP24K3HD75TX

Switchcraft / Conxall

PATCHBAY 24JACK HD TERMINATED

0

TT96EDACNSX

TT96EDACNSX

Switchcraft / Conxall

JACK EDAC 90PIN STRAPPED

0

1200X

1200X

Switchcraft / Conxall

PHONE T-JACK PANEL .25" STD SGL

24

Patchbay, Jack Panels

1. Overview

Boxes, enclosures, racks, patchbays, and jack panels are essential components for organizing, protecting, and managing electrical, electronic, and data systems. Boxes and enclosures provide physical protection for sensitive equipment, while racks offer structured mounting solutions. Patchbays and jack panels serve as centralized hubs for signal routing and connectivity in audio, data, and telecommunications systems. These components ensure operational efficiency, safety, and scalability in modern infrastructure.

2. Main Types and Functional Classification

TypeFunctional FeaturesApplication Examples
BoxesCompact protection for individual devices; options include waterproof, dustproof, and explosion-proof designs.Outdoor telecom equipment, industrial sensors.
EnclosuresModular cabinets for housing multiple devices; support cooling, cable management, and security features.Data centers, server rooms.
RacksStandardized mounting systems (e.g., 19-inch); support vertical/horizontal cable management and load-bearing requirements.IT infrastructure, broadcasting studios.
PatchbaysHigh-density signal routing with fixed/switchable connections; support analog/digital signal types.Recording studios, network operations centers.
Jack PanelsMulti-port connectivity for Ethernet, audio, or video signals; support PoE and high-frequency transmission.Office LANs, security camera systems.

3. Structure and Components

Typical products consist of: - Materials: Steel, aluminum, or polymer shells for durability and EMI shielding. - Internal Components: Mounting rails, cable guides, power distribution units (PDUs), and cooling vents. - Connectivity Elements: RJ45, BNC, XLR, or fiber optic ports for signal/data transmission. - Accessories: Locks, hinges, ventilation fans, and labeling systems for usability and security.

4. Key Technical Specifications

ParameterDescriptionImportance
DimensionsHeight, width, depth (e.g., 42U rack height)Determines compatibility with installation spaces.
Material Thickness1.0 2.5mm steel or equivalentAffects durability and environmental resistance.
Port DensityNumber of ports per unit area (e.g., 24/48 ports)Impacts scalability and space efficiency.
Impedance50 /75 for RF or 100 for EthernetEnsures signal integrity in high-frequency applications.
Load Capacity0 1500kg static load for racksGuarantees structural safety for heavy equipment.

5. Application Fields

Main industries and equipment include: - Telecommunications: Central offices, fiber distribution hubs. - Data Centers: Server racks, network switches. - Broadcasting: Video/audio routers, mixing consoles. - Industrial Automation: PLC enclosures, control boxes. - Commercial Buildings: Structured cabling systems, PoE-powered devices.

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductFeatures
PanduitPanzone EnclosuresIP55 rating, modular cooling options.
SiemonZ-Max PatchbaysCategory 6A compliance, 10G performance.
RittalTS 8 Server RacksDynamic load capacity up to 1800kg.
LevitonOpt-X Jack PanelsLC/MPO fiber connectivity, PoE support.
HubbellMulti-Gang BoxesWeatherproof NEMA 4X design for outdoor use.

7. Selection Guidelines

Key considerations: - Environmental requirements (temperature, humidity, ingress protection). - Scalability for future expansion. - Compatibility with existing infrastructure (e.g., rack units, cable types). - Redundancy and maintenance accessibility. - Regulatory standards (e.g., TIA-942 for data centers).

8. Industry Trends

Emerging trends include: - Modular designs for rapid deployment in edge computing. - Integration of smart sensors for real-time monitoring (IoT-enabled enclosures). - High-density optical solutions for 400G/800G data transmission. - Adoption of recyclable materials to meet sustainability goals. - Standardization of hybrid racks for converged IT/OT environments.

RFQ BOM Call Skype Email
Top