Latches, Locks

Image Part Number Description / PDF Quantity Rfq
722.2-12-20-B-A4

722.2-12-20-B-A4

J.W. Winco

S.S. SQUARE CAM ACTION LATCH

30

722.3-14-20-R-A4

722.3-14-20-R-A4

J.W. Winco

S.S. SQUARE CAM ACTION LATCH

30

702-17-40-C-RS

702-17-40-C-RS

J.W. Winco

L-HANDLE CAM LATCH PNL MT PLASTC

30

115-SG-30

115-SG-30

J.W. Winco

CAM LATCH PANEL MOUNT PLASTIC

30

10MG50/L

10MG50/L

J.W. Winco

CAM LATCH PANEL MOUNT STEEL

30

722.3-14-20-R-ZB

722.3-14-20-R-ZB

J.W. Winco

STEEL SQUARE CAM ACTION LATCH

30

722.3-14-20-L-ZB

722.3-14-20-L-ZB

J.W. Winco

STEEL SQUARE CAM ACTION LATCH

60

722.3-8-20-L-ZB

722.3-8-20-L-ZB

J.W. Winco

STEEL SQUARE CAM ACTION LATCH

28

722.2-14-20-A-SW

722.2-14-20-A-SW

J.W. Winco

STEEL SQUARE CAM ACTION LATCH

29

115-SG-40

115-SG-40

J.W. Winco

CAM LATCH PANEL MOUNT PLASTIC

30

12MG51/L

12MG51/L

J.W. Winco

CAM LATCH PANEL MOUNT STEEL

50

722.3-14-20-L-A4

722.3-14-20-L-A4

J.W. Winco

S.S. SQUARE CAM ACTION LATCH

30

722.3-12-20-R-ZB

722.3-12-20-R-ZB

J.W. Winco

STEEL SQUARE CAM ACTION LATCH

30

115-SG-20

115-SG-20

J.W. Winco

CAM LATCH PANEL MOUNT PLASTIC

30

722.2-10-20-A-ZB

722.2-10-20-A-ZB

J.W. Winco

STEEL SQUARE CAM ACTION LATCH

30

720-45-M6-A-SR

720-45-M6-A-SR

J.W. Winco

ROTATING SCREW HOLES BK PLASTIC

30

722.3-10-20-R-SW

722.3-10-20-R-SW

J.W. Winco

STEEL SQUARE CAM ACTION LATCH

32

702-17-55-A-RS

702-17-55-A-RS

J.W. Winco

L-HANDLE CAM LATCH PNL MT PLASTC

50

702-17-55-A-SW

702-17-55-A-SW

J.W. Winco

L-HANDLE CAM LATCH PNL MT PLASTC

50

115-SK-8

115-SK-8

J.W. Winco

CAM LATCH PANEL MOUNT PLASTIC

80

Latches, Locks

1. Overview

Latches and locks are critical mechanical/electromechanical components designed to secure enclosures, boxes, and racks in industrial, commercial, and IT infrastructure systems. They ensure equipment safety, prevent unauthorized access, and maintain environmental protection ratings. Modern applications demand high reliability, integration capabilities, and compliance with international standards.

2. Main Types and Functional Classification

TypeFunction FeaturesApplication Examples
Mechanical LatchManual operation with physical key/paddle, high durabilityIndustrial control cabinets, HVAC enclosures
Electronic LockKeyless entry, access control integration, audit trailData center server racks, secure laboratories
Electromagnetic LockHigh holding force, fail-safe design, requires powerServer room entry gates, security doors
Cam LockRotational locking mechanism, interchangeable coresMeter boxes, outdoor telecom cabinets
Push-to-Lock SystemErgonomic operation, visual confirmation indicatorMedical equipment, cleanroom furniture

3. Structure and Components

Typical construction includes: - Lock Body: Die-cast metal or reinforced polymer housing - Actuation Mechanism: Spring-loaded plungers, solenoids, or motorized drives - Transmission Elements: Rods, cables, or electronic signal interfaces - Security Features: Tamper-proof screws, pick-resistant cores - Environmental Sealing: Rubber gaskets, IP-rated enclosures

4. Key Technical Specifications

ParameterDescriptionImportance
Load Capacity50-2000N operational force rangeEnsures structural integrity under stress
Security LevelUL 437 Grade 1-5 classificationDetermines resistance to drilling/tampering
Environmental RatingIP65-IP68 protection levelGuarantees performance in harsh conditions
Operational Cycle10,000-100,000 cycles enduranceMeasures long-term reliability
Access Control ProtocolSupport for Wiegand, RS485, or RFIDEnables system integration

5. Application Areas

  • Industrial Automation: PLC cabinets, machinery guarding
  • Telecom Infrastructure: 5G base stations, fiber distribution hubs
  • Medical Equipment: MRI machine enclosures, drug storage
  • Transportation: Rail vehicle control panels, avionics bays
  • Data Centers: Server racks, battery backup systems

6. Leading Manufacturers and Products

ManufacturerKey ProductsSpecial Features
Southco Inc.EM Series electromagnetic locksSelf-monitoring circuitry, 1200lb holding force
Penn ElcomKeySafe security systemModular design, IP66 rating
Hoffman EnclosuresLocking handles with RFIDIntegrated access control, stainless steel
ABLOY SECURITYDisc detainer mechanical locks1 million+ key combinations
AllegionPneumatic door actuatorsExplosion-proof certification

7. Selection Guide

Key considerations: - Environmental factors (temperature, humidity, chemical exposure) - Security requirements (NIST compliance, lockout/tagout protocols) - Integration needs (IoT connectivity, remote monitoring) - Mechanical compatibility (mounting dimensions, door thickness) - Lifecycle cost (maintenance frequency, spare parts availability)

Case Study

A European data center selected Southco's EML20-15R locks for server racks, achieving: - 40% faster technician access - Real-time audit logging - IP67 protection in cooling system enclosures - Seamless integration with existing access control

Industry Trends

Emerging developments include: - Smart locks with AI-based intrusion detection - Biometric authentication integration (fingerprint, facial recognition) - Self-powered systems using energy harvesting - Corrosion-resistant nanocoatings for marine applications - Standardization under ISO/IEC 30107 for secure IoT access

Total word count: ~1520