Box Components

Image Part Number Description / PDF Quantity Rfq
2201502

2201502

Phoenix Contact

BUS CONNECTOR SET 50/40POS

0

2201520

2201520

Phoenix Contact

ELECTRONIC HOUSING COVER

9

2709532

2709532

Phoenix Contact

TERM HOUSING

0

2201774

2201774

Phoenix Contact

ELECTRONIC HOUSING COVER

1

2906759

2906759

Phoenix Contact

TERM HOUSING

0

2200972

2200972

Phoenix Contact

PANEL MOUNT BASE

0

2201097

2201097

Phoenix Contact

ELECTRONIC HOUSING COVER

6

2201963

2201963

Phoenix Contact

ME-IO 18 8 B/FE 3/9U TBUS 7035

0

2901369

2901369

Phoenix Contact

HOUSING PLSTC GRAY 3.35"LX0.69"W

20

2200660

2200660

Phoenix Contact

HOUSING BLUE

0

2790871

2790871

Phoenix Contact

CONN HOUSING SCREW TYPE 8 POS

1

2200174

2200174

Phoenix Contact

ELECTRONIC HOUSING

0

2278526

2278526

Phoenix Contact

UPPER PART HOUSING BC 161.6MM

98

2201844

2201844

Phoenix Contact

ELECTRONIC HOUSING COVER CAP

4

2203894

2203894

Phoenix Contact

FILLER PLUGS

120

2200939

2200939

Phoenix Contact

PANEL MOUNT BASE

0

2201806

2201806

Phoenix Contact

ME-IO 18 8 C 9U 7035

0

2946023

2946023

Phoenix Contact

HOUSING TERMINAL BLOCK AND COVER

0

2854199

2854199

Phoenix Contact

TERM HOUSING

0

2941510

2941510

Phoenix Contact

TERM BLOCK/SCREW COVER 50STRIPS

0

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top