Box Components

Image Part Number Description / PDF Quantity Rfq
2707767

2707767

Phoenix Contact

TERM HOUSING

11

1076892

1076892

Phoenix Contact

DIN RAIL HOUSING, UPPER PART, CL

40

2201826

2201826

Phoenix Contact

ELECTRONIC HOUSING COVER

46

2955593

2955593

Phoenix Contact

SIDE ELEMENT

15

2908980

2908980

Phoenix Contact

HOUSING UPPER FOR PCB TERM BLOCK

40

2942991

2942991

Phoenix Contact

TERM BLOCK HOUSING

4

2896144

2896144

Phoenix Contact

COVER

12

2201250

2201250

Phoenix Contact

ELECTRONIC HOUSING COVER

22

2908414

2908414

Phoenix Contact

TERM HOUSING

0

2896160

2896160

Phoenix Contact

COVER FOR INSTALLATION HOUSING

5

2230007

2230007

Phoenix Contact

FACEPLATE, COLOR: BLACK, WIDTH:

7320

2706438

2706438

Phoenix Contact

TERM HOUSING

0

2908016

2908016

Phoenix Contact

ME22,5OT-MKDSOBU

0

2946081

2946081

Phoenix Contact

CIRCUIT MODULE W/HOUSING

2

2709545

2709545

Phoenix Contact

TERM HOUSING

0

2201738

2201738

Phoenix Contact

ELECTRONIC HOUSING BASE

8

2201388

2201388

Phoenix Contact

ELECTRONIC HOUSING COVER

44

2947996

2947996

Phoenix Contact

CIRCUIT MODULE W/HOUSING

0

2707929

2707929

Phoenix Contact

TERMINAL POINTS FILLER PLUG

5499960

2200323

2200323

Phoenix Contact

HOUSING UPPER BRACKET ME22

10

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top