Box Components

Image Part Number Description / PDF Quantity Rfq
2707754

2707754

Phoenix Contact

TERM HOUSING

0

2201919

2201919

Phoenix Contact

BC 161 6 OT 111122 KMGY

10340

2713052

2713052

Phoenix Contact

TERMINAL COVER 12POS

0

2201516

2201516

Phoenix Contact

ELECTRONIC HOUSING COVER

10

2896157

2896157

Phoenix Contact

COVER FOR INSTALLATION HOUSING

153

2735564

2735564

Phoenix Contact

TERM HOUSING

0

2906490

2906490

Phoenix Contact

SIDE ELEMENT LEFT W/FOOT

18

2202019

2202019

Phoenix Contact

HOUSING COMPONENT

0

1076893

1076893

Phoenix Contact

DIN RAIL HOUSING, LOWER HOUSING

195

2896092

2896092

Phoenix Contact

UPPER PART INSTALLATION HOUSING

0

2707495

2707495

Phoenix Contact

ME 22 5 OT-1MSTBO BK

0

2947983

2947983

Phoenix Contact

HOUSING PLSTC GRN 2.95"LX4.92"W

0

2869032

2869032

Phoenix Contact

TERM HOUSING

0

2908948

2908948

Phoenix Contact

TERM HOUSING

0

2907910

2907910

Phoenix Contact

HOUSING TERM BLOCK

0

2201837

2201837

Phoenix Contact

ELECTRONIC HOUSING COVER

2

2201832

2201832

Phoenix Contact

ELECTRONIC HOUSING COVER

10

2200336

2200336

Phoenix Contact

ELECTRONIC HOUSING COVER

0

2200952

2200952

Phoenix Contact

PANEL MOUNT BASE

0

2201835

2201835

Phoenix Contact

ELECTRONIC HOUSING COVER

1

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top