Box Components

Image Part Number Description / PDF Quantity Rfq
R507-104-000

R507-104-000

Hammond Manufacturing

PANEL INTERNAL 2MM ZINC PLATED

0

N1JP2012

N1JP2012

Hammond Manufacturing

PANEL INNER 18.3X10.3" GRAY

0

R530-164-000

R530-164-000

Hammond Manufacturing

PANEL INNER 0.059"

0

N1JP1010

N1JP1010

Hammond Manufacturing

PANEL INNER 8.25X8.25" GRAY

0

F3024

F3024

Hammond Manufacturing

FIBERGLASS INNER PANEL

0

1455KBRED

1455KBRED

Hammond Manufacturing

BEZEL OPEN PLASTIC RED 2/PACK

0

PJSPU1614

PJSPU1614

Hammond Manufacturing

PANEL SWING PJU 15.64X13.86"

0

N1JP86PP

N1JP86PP

Hammond Manufacturing

INNER PANEL

0

1481WFL52

1481WFL52

Hammond Manufacturing

WINDOW FRAMELESS 5.50X3"

0

ECPP1620

ECPP1620

Hammond Manufacturing

PANEL ALUM 16.25X14"

0

ESP1616

ESP1616

Hammond Manufacturing

PANEL STEEL SWING 16X16" WHT

0

R507-100-000

R507-100-000

Hammond Manufacturing

PANEL INTERNAL 2MM ZINC PLATED

0

N1JP108PP

N1JP108PP

Hammond Manufacturing

INNER PANEL

0

031623

031623

Hammond Manufacturing

END PANELS ALUMINUM BLACK

19

ESP3024

ESP3024

Hammond Manufacturing

PANEL STEEL SWING 30X24" WHT

0

N1JP1412

N1JP1412

Hammond Manufacturing

PANEL INNER 12.3X10.3" GRAY

0

R507-084-000

R507-084-000

Hammond Manufacturing

PANEL INTERNAL 2MM ZINC PLATED

0

R507-322-000

R507-322-000

Hammond Manufacturing

PANEL INTERNAL 2MM ZINC PLATED

0

N1JP1212PP

N1JP1212PP

Hammond Manufacturing

INNER PANEL

0

R507-160-000

R507-160-000

Hammond Manufacturing

PANEL INTERNAL 2MM ZINC PLATED

0

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications