Box Components

Image Part Number Description / PDF Quantity Rfq
043860

043860

ERNI Electronics

ENCL LDG-A 12 LEFT TERM BLOCK

161

054248

054248

ERNI Electronics

ENCL LDG-A 16 FRAME INSERT

200

224074

224074

ERNI Electronics

ENCL LDG-A CLAMP PIN 32MM

1000

413962

413962

ERNI Electronics

ENCL LDG-A 30 COVER

75

014415

014415

ERNI Electronics

ENCL LDG-A 16 COVER LIGHT GREY

150

053164

053164

ERNI Electronics

ENCL LDG-A 30 FRAME INSERT

360

914840

914840

ERNI Electronics

ENCL LDG-A 16 WIDE TERM BLOCK

150

914810

914810

ERNI Electronics

ENCL LDG-A 14 NARROW TERM BLOCK

80

024870

024870

ERNI Electronics

ENCL LDG-A 16 BASE WITH VENT

120

014818

014818

ERNI Electronics

ENCL LDG-A 46 COVER GREY

100

053869

053869

ERNI Electronics

ENCL LDG-A 16 FRAME INSERT

1000

414463

414463

ERNI Electronics

ENCL LDG-A 12 COVER

149

014416

014416

ERNI Electronics

ENCL LDG-A 16 TRANSPARENT COVER

300

024080

024080

ERNI Electronics

ENCL LDG-A 46 BASE PART VENT

135

053871

053871

ERNI Electronics

ENCL LDG-A 16 BLIND INSERT

1000

223795

223795

ERNI Electronics

ENCL LDG-A 14-70 SCREW CLAMP

800

914830

914830

ERNI Electronics

ENCL LDG-A 16 NARROW TERM BLOCK

100

914860

914860

ERNI Electronics

ENCL LDG-A 30 WIDE TERM BLOCK

92

014819

014819

ERNI Electronics

ENCL LDG-A 46 TRANSPARENT COVER

150

224076

224076

ERNI Electronics

ENCL LDG-A CLAMP PIN 18MM

580

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top