Box Components

Image Part Number Description / PDF Quantity Rfq
PNX-91432

PNX-91432

Bud Industries, Inc.

PANEL ALUM 5.91X2.76X0.06"

243

6103FP-RB-PK

6103FP-RB-PK

Bud Industries, Inc.

FRONT PANEL FOR TR6103 CABINET

0

ANX-91301

ANX-91301

Bud Industries, Inc.

PANEL ALUM 2.13X1.87X0.06"

0

NBX-10978

NBX-10978

Bud Industries, Inc.

PANEL INTERNAL 2.56 X 9.25"

17

PNX-91425

PNX-91425

Bud Industries, Inc.

PANEL ALUM 8.27X5.27X0.06"

0

BPA-1515

BPA-1515

Bud Industries, Inc.

PLATE ALUMINUM BOTTOM 6" X 17"

35

CSC-11244

CSC-11244

Bud Industries, Inc.

CHASSIS FOR CHAMPION 8.25X6.06"

2

BPA-1504

BPA-1504

Bud Industries, Inc.

PLATE ALUMINUM BOTTOM 4" X 5"

48

PNX-92602

PNX-92602

Bud Industries, Inc.

PANEL ALUM 4.37X2.8X0.06"

45

PUX-16538

PUX-16538

Bud Industries, Inc.

PU-16538 ALUMINUM INTERNAL PANEL

399

NBX-10976

NBX-10976

Bud Industries, Inc.

PANEL INTERNAL 2.56 X 4.55"

15

CSC-11246

CSC-11246

Bud Industries, Inc.

CHASSIS FOR CHAMPION 11.25X6.06"

5

BPA-1502

BPA-1502

Bud Industries, Inc.

PLATE ALUMINUM BOTTOM 3.5 X 4.5"

367

PWX-12846

PWX-12846

Bud Industries, Inc.

ALUMINUM INTERNAL PANEL FOR PW-1

594

DMB-4772-IRC

DMB-4772-IRC

Bud Industries, Inc.

IR COVER FOR DMB-4772

80

ANX-91320

ANX-91320

Bud Industries, Inc.

PANEL ALUM 3.66X1.69X0.06"

33

PNX-91423

PNX-91423

Bud Industries, Inc.

PANEL ALUM 4.02X3.03X0.06"

386

PBC-1581-C

PBC-1581-C

Bud Industries, Inc.

COVER ABS FOR PB-1581-TF 1=10PCS

9180

PNX-91438

PNX-91438

Bud Industries, Inc.

PANEL ALUM 5.87X5.87X0.06"

0

BPA-1514

BPA-1514

Bud Industries, Inc.

PLATE ALUMINUM BOTTOM 6" X 14"

182

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top