Box Components

Image Part Number Description / PDF Quantity Rfq
79001900

79001900

Rose+Krieger

CENTER SECTION 1.0 147X176X88MM

0

79003300

79003300

Rose+Krieger

FRONT COVER 147X323X34MM CLEAR

0

BCD 200 OT-G-7035

BCD 200 OT-G-7035

Rose+Krieger

HINGED LID 204X229X36MM

0

BCD 200 KRD-7024

BCD 200 KRD-7024

Rose+Krieger

TERM COMPART LID 218X54X20MM

0

BCD 200 OT-F-7035

BCD 200 OT-F-7035

Rose+Krieger

MEMBRANE LID 203X229X19MM

0

79003600

79003600

Rose+Krieger

FRAME FRONT OPEN 147X323X34MM

0

79001700

79001700

Rose+Krieger

CENTER SECTION 1.0 147X226X88MM

0

BCD 160 OT-G-7024

BCD 160 OT-G-7024

Rose+Krieger

HINGED LID 179X199X36.5

0

79003000

79003000

Rose+Krieger

FRONT COVER 147X323X34MM GRAY

0

BCD 160 KRD-7024

BCD 160 KRD-7024

Rose+Krieger

TERM COMPART LID 44X188X19.5MM

0

07071201 30

07071201 30

Rose+Krieger

ENCL LID DI-CAST RAL 9005

0

BCD 160 KRD-7035

BCD 160 KRD-7035

Rose+Krieger

TERM COMPART LID 44X188X19.5MM

0

79001910

79001910

Rose+Krieger

BASE NG VENT 170X204X68MM PNL MT

0

79000300

79000300

Rose+Krieger

REAR COVER ABS 147X323X50MM

0

BCD 250 FO-7024

BCD 250 FO-7024

Rose+Krieger

OPEN FRONT FRAME 233X264X19MM

0

BCD 200 OT-F-7024

BCD 200 OT-F-7024

Rose+Krieger

MEMBRANE LID 203X229X19MM

0

BCD 250 OT-F-7024

BCD 250 OT-F-7024

Rose+Krieger

MEMBRANE LID 233X264X19MM

0

FP30014/56031400

FP30014/56031400

Rose+Krieger

REAR PNL, ALUM, 5.87"X3.23"

0

79002600

79002600

Rose+Krieger

CENTER SECTION 1.5 147X226X140MM

0

79000400

79000400

Rose+Krieger

REAR COVER W/TERMINAL COMPART

0

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top