Box Components

Image Part Number Description / PDF Quantity Rfq
96706300

96706300

Rose+Krieger

BOCUBE B FP 2617 FRNT PNL 2.5MM

0

BE 60

BE 60

Rose+Krieger

BATTERY COMPARTMENT 2(9V)OR4(AA)

5

96310200

96310200

Rose+Krieger

PC-V0-3000 HINGE LOCK 130 MM

2

96310304

96310304

Rose+Krieger

PC-V0-7024 HINGE LOCK 170MM

0

96310105

96310105

Rose+Krieger

PC-V0-7035 HINGE LOCK 80MM

0

96310305

96310305

Rose+Krieger

PC-V0-7035 HINGE LOCK 170MM

0

96703100

96703100

Rose+Krieger

BOCUBE B FP 1408 FRNT PNL 1.5MM

0

BE 30

BE 30

Rose+Krieger

BATTERY COMPARTMENT 1(9V)OR2(AA)

347

96705200

96705200

Rose+Krieger

BOCUBE B FP 2213 FRNT PNL 2MM

1

96310109

96310109

Rose+Krieger

PC-V0-6029 HINGE LOCK 80 MM

169

96702100

96702100

Rose+Krieger

BOCUBE B FP 1008 FRNT PNL 1.5MM

0

79002110

79002110

Rose+Krieger

NG BASE VENT 170X351X68MM PNL MT

0

79003800

79003800

Rose+Krieger

FRAME FRONT CLOSED 147X226X34MM

0

BCD 160 FO-K-7024

BCD 160 FO-K-7024

Rose+Krieger

FRONT FRAME W/COVER 178X199X19MM

0

BCD 250 OT-G-7035

BCD 250 OT-G-7035

Rose+Krieger

HINGED LID 234X264X36MM

0

BCD 200 FO-7035

BCD 200 FO-7035

Rose+Krieger

OPEN FRONT FRAME 203X229X19MM

0

79001810

79001810

Rose+Krieger

BASE NG 170X351X68MM PNL MNT

0

BCD 250 OT-F-7035

BCD 250 OT-F-7035

Rose+Krieger

MEMBRANE LID 233X264X19MM

0

79000100

79000100

Rose+Krieger

REAR COVER ABS 147X176X50MM

0

BCD 400 OT-G-7035

BCD 400 OT-G-7035

Rose+Krieger

HINGED CLEAR LID 344X404X37.5MM

0

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top