Box Components

Image Part Number Description / PDF Quantity Rfq
30848328

30848328

Schroff / nVent

FRNT PNL 3U 5HP TYP 2 EXTRCT HDL

0

20817452

20817452

Schroff / nVent

FRONT PANEL KIT 6U 8HP VME

10

30848338

30848338

Schroff / nVent

FRNT PNL 6U 6HP TYP 2 EXTRCT HDL

0

30807481

30807481

Schroff / nVent

FRONT PANEL 3U 4HP (ANODIZED)

0

30848331

30848331

Schroff / nVent

FRNT PNL 3U 8HP TYP 2 EXTRCT HDL

0

30848333

30848333

Schroff / nVent

FRT PNL 3U 10HP TYP 2 EXTRCT HDL

0

30848312

30848312

Schroff / nVent

FRNT PNL 3U 4HP TYP 2 EXTRCT HDL

64

20818019

20818019

Schroff / nVent

FRONT PANEL KIT 3U 5HP VME

35

20848487

20848487

Schroff / nVent

FRONT PANEL KIT 3U 6HP FOR VME

0

20848672

20848672

Schroff / nVent

FRONT PANEL KIT 6U 4HP FOR VME

0

20848589

20848589

Schroff / nVent

FRNT PNL KIT 3U 8HP CPCI-VME64X

12

20848594

20848594

Schroff / nVent

FRNT PNL KIT 6U 6HP CPCI-VME64X

5

20846426

20846426

Schroff / nVent

FRNT FILLER PNL 3U 4HP SHLD ALUM

0

30848315

30848315

Schroff / nVent

FRT PNL 3U 10HP TYP 2 EXTRCT HDL

0

20848611

20848611

Schroff / nVent

FRONT PANEL 3U 84HP SIDE HINGED

0

20848492

20848492

Schroff / nVent

FRONT PANEL KIT 6U 4HP FOR VME

12

20848601

20848601

Schroff / nVent

FRNT PNL 3U 84HP VME-VME64X

0

20818020

20818020

Schroff / nVent

FRONT PANEL KIT 3U 6HP VME

1

20848496

20848496

Schroff / nVent

FRONT PANEL KIT 6U 8HP FOR VME

12

30847603

30847603

Schroff / nVent

FRNT PNL 3U 4HP VME STATIC HANDL

0

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top