Box Components

Image Part Number Description / PDF Quantity Rfq
0196600000

0196600000

Weidmuller

TERMINAL,FEED THRU,25MMX31.6MM

0

1137750000

1137750000

Weidmuller

CH20M45 S 3SC/2PSC BK

0

1254170000

1254170000

Weidmuller

CH20M17 S PPP BK

0

4053240000

4053240000

Weidmuller

PF RS 90 OR 2M

0

1254180000

1254180000

Weidmuller

CH20M17 B BUS BK/OR

0

2062740000

2062740000

Weidmuller

RS-70 ZW 45 HOUSING

503

950398

950398

Weidmuller

TBF6 HINGED COVER -

0

1312680000

1312680000

Weidmuller

CH20M 12 S PSCSC LGY

0

9444010000

9444010000

Weidmuller

RS30-NV 24VDC

0

1235310000

1235310000

Weidmuller

CH20M67 FC BK

0

1519520000

1519520000

Weidmuller

CH20M45 SET 33/33 BK/OR

0

0453660000

0453660000

Weidmuller

EG 32/EG 35 AP

60

1177020000

1177020000

Weidmuller

CH20M45 B BUS BK/OR

0

1961890000

1961890000

Weidmuller

HOUSING END PLATE GRAY

0

8156200000

8156200000

Weidmuller

END PLATE 9MM GRAY

40

1410960000

1410960000

Weidmuller

CONN END PLATE 12.3MM ORG

0

2435720000

2435720000

Weidmuller

FLANGE-MOUNTED HOUSING, OMNIMATE

0

1189870000

1189870000

Weidmuller

ELECTRONICS HOUSINGS, RS 100 BL

0

2435440000

2435440000

Weidmuller

FLANGE-MOUNTED HOUSING, OMNIMATE

0

C9025766

C9025766

Weidmuller

RS 100 PROFILE 75MM GRAY

0

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications