Box Components

Image Part Number Description / PDF Quantity Rfq
2970442

2970442

Phoenix Contact

UNIVERS MOD SIDE ELEMENT 11.25MM

6961450

EPG3030

EPG3030

Hammond Manufacturing

PANEL STEEL 28.2 X 28.2"

0

1455NBRED-10

1455NBRED-10

Hammond Manufacturing

BEZEL OPEN PLASTIC RED 10/PACK

10

1481WSSDH2416

1481WSSDH2416

Hammond Manufacturing

WINDOW DEEP HINGE 22.19X12.14"

0

30848339

30848339

Schroff / nVent

FRNT PNL 6U 7HP TYP 2 EXTRCT HDL

0

A12P10AL

A12P10AL

nVent Hoffman

PANEL J BOX 10.75X8.88

8

2713010

2713010

Phoenix Contact

TERM HOUSING

0

2003DB25

2003DB25

Serpac Electronic Enclosures

END PANEL W/DB25 FOR A-20 BLK

228

4144870000

4144870000

Weidmuller

HOUSING PROFILE STRIP 2 METER

37178

20848591

20848591

Schroff / nVent

FRNT PNL KIT 3U 12HP CPCI-VME64X

18

2947938

2947938

Phoenix Contact

COVER FOR THE CONTACT 50 MM

0

PIX-11775

PIX-11775

Bud Industries, Inc.

STEEL INTERNAL PANEL - PIP

45173

1481L3R88GY

1481L3R88GY

Hammond Manufacturing

VENT KIT GRAY

0

BPA-1530

BPA-1530

Bud Industries, Inc.

CHASS BOT PLATE ALUM 15 X 17 NAT

3017

2914327

2914327

Phoenix Contact

ME 22 5 UT/FE TBUS KMGY

5

2907826

2907826

Phoenix Contact

SIDE ELEMENT W/FOOT

16

2200546

2200546

Phoenix Contact

ELECTRONIC HOUSING

0

2201522

2201522

Phoenix Contact

ELECTRONIC HOUSING COVER

0

A16P16

A16P16

nVent Hoffman

PANEL NEMA 12 13.00X13.00

2

LFK68

LFK68

Hammond Manufacturing

VENT FILTER METAL

0

Box Components

1. Overview

Box components refer to modular hardware elements designed for housing, organizing, and protecting electronic, electrical, or mechanical systems. These components include enclosures, racks, panels, and associated accessories that provide structural support, environmental protection, and cable management. They play a critical role in ensuring system reliability, safety, and maintainability across industries such as IT infrastructure, industrial automation, telecommunications, and energy management.

2. Major Types and Functional Classification

TypeFunctional FeaturesApplication Examples
Rack EnclosuresVertical/horizontal mounting, cable management, thermal controlData center server racks, network closets
Wall-Mount BoxesCompact design, wall installation, IP protection ratingIndustrial control panels, HVAC systems
Modular RacksCustomizable bays, toolless installation, vibration resistanceTelecom base stations, laboratory equipment
Cable Management PanelsHorizontal/vertical cable routing, strain reliefEnterprise network cabinets, data centers
Thermal Management KitsFan modules, heat exchangers, temperature monitoringOutdoor telecom cabinets, power conversion systems

3. Structure and Composition

Typical box components consist of: - Frame Structure: Cold-rolled steel or aluminum alloy with corrosion-resistant coatings - Mounting System: Standard 19" rack rails, DIN rails, or custom mounting brackets - Access Panels: Removable side panels, hinged doors with locking mechanisms - Internal Components: Cable trays, grounding bars, PSU mounting zones - Thermal System: Ventilation grills, fan trays, or liquid cooling interfaces Modular designs often feature toolless assembly and IP20-IP66 protection ratings for diverse environments.

4. Key Technical Specifications

ParameterImportanceTypical Values
Load CapacityDetermines equipment weight support50-1500 kg
Material ThicknessAffects durability and EMI shielding0.8-2.5 mm steel
Thermal DissipationEnsures component longevity50-500 W/m
IP RatingDefines environmental protection levelIP20 (indoor) to IP66 (outdoor)
Rack Unit (RU) SizeStandardizes mounting compatibility1U-42U heights

5. Application Fields

Key industries utilizing box components include: - IT Infrastructure: Server racks, data center enclosures - Industrial Automation: PLC control cabinets, factory HMI stations - Telecommunications: 5G base station cabinets, fiber distribution hubs - Energy Systems: Solar inverter enclosures, battery management racks - Medical Equipment: Diagnostic imaging system housings

6. Leading Manufacturers and Products

ManufacturerRepresentative Products
PanduitNetShelter VX Server Cabinet
RittalTS 8 Modular Enclosure System
Schneider ElectricEnclosures & Rack Solutions
Hammond Manufacturing1590 Series Wall Mount Boxes
SiemensSIVACON S4 Low Voltage Switchgear

7. Selection Recommendations

Key considerations for selection: - Environmental Factors: Temperature range (-40 C to +70 C), humidity, and dust exposure - Space Planning: RU count, depth requirements for servers or equipment - Cable Management: Required entry points and bend radius clearance - Future Expansion: 20% - Compliance: Adherence to EIA-310, IEC 60298 standards

8. Industry Trends

Emerging trends shaping box component design: - Smart Integration: Embedded sensors for real-time temperature/vibration monitoring - Energy Efficiency: Optimized airflow designs reducing cooling costs by 30% - Material Innovation: Composite polymers cutting weight by 40% vs. steel - Edge Computing Focus: Compact outdoor enclosures for 5G/edge deployments - Customization: 3D-printed bespoke components for specialized applications

RFQ BOM Call Skype Email
Top