Switching Converter, SMPS Transformers

Image Part Number Description / PDF Quantity Rfq
749196521

749196521

Würth Elektronik Midcom

TRANSFORMER 12UH 1.7A SMD

191

749196211

749196211

Würth Elektronik Midcom

WE-FLEX FLEXIBLE TRANSFORMER FOR

241

760895441

760895441

Würth Elektronik Midcom

WE-LLCR RESONANT CONVERTER 600UH

5

750314744

750314744

Würth Elektronik Midcom

FLYBACK TRANSFORMER WE-FB

0

750811611

750811611

Würth Elektronik Midcom

SMD OFFLINE TRANSFORMER WE-UNIT

240

749119450

749119450

Würth Elektronik Midcom

TRANS FLYBACK POE+ 65UH SMD

17

760875532

760875532

Würth Elektronik Midcom

TRANSFORMER OFFLINE 1.5MH 4000V

149

750310562

750310562

Würth Elektronik Midcom

TRANS FLYBACK LT3573 25UH SMD

928

750311267

750311267

Würth Elektronik Midcom

TRANS FLYBACK ON SEMI NCP1652

0

750315833

750315833

Würth Elektronik Midcom

FLYBACK TRANSFORMER WE-FB

0

750811290

750811290

Würth Elektronik Midcom

TRANSFORMER FLYBACK LT3799

36

760871333

760871333

Würth Elektronik Midcom

TRANSFORMER OFFLINE SMD

31

760871631

760871631

Würth Elektronik Midcom

TRANS FLYBACK NXP TEA1733 2.2MH

0

750310377

750310377

Würth Elektronik Midcom

POWER OVER ETHERNET UEBERTRAGER

0

750342156

750342156

Würth Elektronik Midcom

FLYBUCK POWER TRANSFORMER

0

750813540

750813540

Würth Elektronik Midcom

TRANS 3000V SMD

0

750341087

750341087

Würth Elektronik Midcom

PWR XFRM LM3440

58

750813550

750813550

Würth Elektronik Midcom

OFFLINE XFRM WE-UNIT TI LM3450

0

750315240

750315240

Würth Elektronik Midcom

XFRMR FWD P-P DC/DC CONV SMD

145

750316030

750316030

Würth Elektronik Midcom

PUSH-PULL TRANSFORMER WE-PP

125

Switching Converter, SMPS Transformers

1. Overview

Switching Mode Power Supply (SMPS) Transformers are critical components in power electronics systems, enabling efficient voltage conversion through high-frequency switching techniques. Unlike traditional linear transformers, SMPS transformers operate at frequencies typically above 20 kHz, allowing reduced size, weight, and improved energy efficiency. These components are essential for modern power management solutions in electronics, renewable energy systems, and industrial automation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Discontinuous Mode (DCM) FlybackGalvanic isolation, single-switch controlAC-DC adapters, battery chargers
Continuous Mode (CCM) FlybackHigher power density, lower ripple currentLED drivers, industrial power supplies
Forward ConverterEfficient for medium power levels, requires reset circuitServer power supplies, telecom equipment
Push-PullBalanced magnetic utilization, high efficiencyHigh-end audio amplifiers, welding machines
Half-Bridge/Full-BridgeHigh power capability, symmetrical switchingElectric vehicle charging, solar inverters

3. Structure and Components

Typical SMPS transformer construction includes:

  • Core materials: Ferrite (Mn-Zn or Ni-Zn), Powdered Iron, Amorphous alloys
  • Winding configuration: Primary/secondary windings with optimized turn ratios
  • Insulation system: Bobbins, tape insulation, and potting compounds
  • Termination: Tin-plated copper leads or surface-mount pads
  • Shielding: Electrostatic shields for EMI reduction

4. Key Technical Specifications

ParameterImportance
Input Voltage RangeDetermines compatibility with power sources
Output Power RatingDefines maximum energy transfer capability
Switching FrequencyImpacts size, efficiency, and EMI performance
Turns Ratio AccuracyAffects voltage regulation precision
Isolation VoltageEnsures safety and dielectric strength
Efficiency (Typical >90%)Reduces thermal management requirements
Operating TemperatureDetermines reliability in harsh environments

5. Application Fields

Major application sectors include:

  • Consumer Electronics: Mobile device chargers, laptop adapters
  • Industrial: Motor drives, PLC power supplies, test equipment
  • Telecommunications: Base station power systems, optical network equipment
  • Renewable Energy: Solar inverters, energy storage systems
  • Automotive: On-board chargers (OBC), DC-DC converters
  • Medical: Isolated power supplies for diagnostic equipment

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
TDK-LambdaPWM Switching TransformerHigh-density design, 150kHz operating frequency
CoilcraftXEL60xx SeriesUltra-low profile, 25A saturation current
Pulse ElectronicsPA5477NLIntegrated EMI filtering, automotive qualified
Bel/Signal Transformer125-2011-FMedical-grade isolation, 4kV withstand
Delta ElectronicsTMA-101-01High-efficiency (94%), 1kW power rating

7. Selection Guidelines

Key considerations for optimal selection:

  1. Power requirements (continuous vs peak load)
  2. Switching frequency compatibility with controller ICs
  3. Thermal management capabilities
  4. Creepage/clearance distances for safety certification
  5. Cost-performance trade-offs
  6. Package dimensions and mounting requirements
  7. Compliance with standards (UL, IEC, AEC-Q)

8. Industry Trends

Current development directions include:

  • Miniaturization through higher operating frequencies (>1MHz)
  • Integration with wide-bandgap semiconductors (GaN/SiC)
  • Advanced nanocrystalline core materials
  • AEC-Q qualified components for automotive electrification
  • Smart transformers with embedded sensing
  • RoHS-compliant, halogen-free construction

Market forecasts indicate 8.2% CAGR through 2028, driven by 5G infrastructure and renewable energy adoption.

RFQ BOM Call Skype Email
Top