Switching Converter, SMPS Transformers

Image Part Number Description / PDF Quantity Rfq
POE13W3VERS-R

POE13W3VERS-R

PowerStor (Eaton)

TRANSFRMR 100UH 13W 1.7A 12P SMD

0

PA3855.006NLT

PA3855.006NLT

PulseLarsen Antenna

TRANSFORMER FLYBACK 21UH SMD

2617

750315835

750315835

Würth Elektronik Midcom

XFRMR FLYBACK DC/DC CONV SMD

136

750316566

750316566

Würth Elektronik Midcom

FLYBACK TRANSFORMER EP5 SMT; UI

334

POE13W3X5.0-R

POE13W3X5.0-R

PowerStor (Eaton)

TRANSFRMR 100UH 13W 1.6A 12P SMD

0

VP4-0140-R

VP4-0140-R

PowerStor (Eaton)

PULSE XFMR 11.3UH SMD

39

750311594

750311594

Würth Elektronik Midcom

TRANS FLYBACK LT3748 15UH SMD

0

750310787

750310787

Würth Elektronik Midcom

TRANS FLYBACK TPS92010DR 2.8MH

0

PA2369NL

PA2369NL

PulseLarsen Antenna

TRANSFORMER SWITCH MODE 5A

1617

POE4W3X5.0-R

POE4W3X5.0-R

PowerStor (Eaton)

XFRMR 200UH 4A 0.10A POE/PD

0

760871038

760871038

Würth Elektronik Midcom

OFFLINE TRANSFORMER WE-UNIT

0

750343004

750343004

Würth Elektronik Midcom

FLYBACK TRANSFORMER WE-FB

0

750313769

750313769

Würth Elektronik Midcom

TRANSFORMER SMD

333

PH0802CNLT

PH0802CNLT

PulseLarsen Antenna

XFMR, ER19 PLANAR, 4:5:2:2, SMT

0

749196228

749196228

Würth Elektronik Midcom

WE-FLEX FLEXIBLE TRANSFORMER FOR

0

PH0809CNLT

PH0809CNLT

PulseLarsen Antenna

XFMR, ER19 PLANAR, 5:6:1:1 SMT

0

7508110101

7508110101

Würth Elektronik Midcom

TRANS OFF LINE POWER PI LNK616

0

7491196501

7491196501

Würth Elektronik Midcom

TRANS FLYBACK POE SMD

49

7491182124

7491182124

Würth Elektronik Midcom

TRANSFORMER OFF LINE 4000V

0

VP3-0055-R

VP3-0055-R

PowerStor (Eaton)

PULSE XFMR 4.5UH SMD

724

Switching Converter, SMPS Transformers

1. Overview

Switching Mode Power Supply (SMPS) Transformers are critical components in power electronics systems, enabling efficient voltage conversion through high-frequency switching techniques. Unlike traditional linear transformers, SMPS transformers operate at frequencies typically above 20 kHz, allowing reduced size, weight, and improved energy efficiency. These components are essential for modern power management solutions in electronics, renewable energy systems, and industrial automation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Discontinuous Mode (DCM) FlybackGalvanic isolation, single-switch controlAC-DC adapters, battery chargers
Continuous Mode (CCM) FlybackHigher power density, lower ripple currentLED drivers, industrial power supplies
Forward ConverterEfficient for medium power levels, requires reset circuitServer power supplies, telecom equipment
Push-PullBalanced magnetic utilization, high efficiencyHigh-end audio amplifiers, welding machines
Half-Bridge/Full-BridgeHigh power capability, symmetrical switchingElectric vehicle charging, solar inverters

3. Structure and Components

Typical SMPS transformer construction includes:

  • Core materials: Ferrite (Mn-Zn or Ni-Zn), Powdered Iron, Amorphous alloys
  • Winding configuration: Primary/secondary windings with optimized turn ratios
  • Insulation system: Bobbins, tape insulation, and potting compounds
  • Termination: Tin-plated copper leads or surface-mount pads
  • Shielding: Electrostatic shields for EMI reduction

4. Key Technical Specifications

ParameterImportance
Input Voltage RangeDetermines compatibility with power sources
Output Power RatingDefines maximum energy transfer capability
Switching FrequencyImpacts size, efficiency, and EMI performance
Turns Ratio AccuracyAffects voltage regulation precision
Isolation VoltageEnsures safety and dielectric strength
Efficiency (Typical >90%)Reduces thermal management requirements
Operating TemperatureDetermines reliability in harsh environments

5. Application Fields

Major application sectors include:

  • Consumer Electronics: Mobile device chargers, laptop adapters
  • Industrial: Motor drives, PLC power supplies, test equipment
  • Telecommunications: Base station power systems, optical network equipment
  • Renewable Energy: Solar inverters, energy storage systems
  • Automotive: On-board chargers (OBC), DC-DC converters
  • Medical: Isolated power supplies for diagnostic equipment

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
TDK-LambdaPWM Switching TransformerHigh-density design, 150kHz operating frequency
CoilcraftXEL60xx SeriesUltra-low profile, 25A saturation current
Pulse ElectronicsPA5477NLIntegrated EMI filtering, automotive qualified
Bel/Signal Transformer125-2011-FMedical-grade isolation, 4kV withstand
Delta ElectronicsTMA-101-01High-efficiency (94%), 1kW power rating

7. Selection Guidelines

Key considerations for optimal selection:

  1. Power requirements (continuous vs peak load)
  2. Switching frequency compatibility with controller ICs
  3. Thermal management capabilities
  4. Creepage/clearance distances for safety certification
  5. Cost-performance trade-offs
  6. Package dimensions and mounting requirements
  7. Compliance with standards (UL, IEC, AEC-Q)

8. Industry Trends

Current development directions include:

  • Miniaturization through higher operating frequencies (>1MHz)
  • Integration with wide-bandgap semiconductors (GaN/SiC)
  • Advanced nanocrystalline core materials
  • AEC-Q qualified components for automotive electrification
  • Smart transformers with embedded sensing
  • RoHS-compliant, halogen-free construction

Market forecasts indicate 8.2% CAGR through 2028, driven by 5G infrastructure and renewable energy adoption.