Power Transformers

Image Part Number Description / PDF Quantity Rfq
182Q6

182Q6

Hammond Manufacturing

PWR XFMR TORO 80VA CHAS MT

0

162D12

162D12

Hammond Manufacturing

PWR XFMR LAMINATED 1.1VA TH

40

266G9

266G9

Hammond Manufacturing

PWR XFMR LAMINATED 4.5VA CHAS MT

9

182N9

182N9

Hammond Manufacturing

PWR XFMR TORO 80VA CHAS MT

0

227R

227R

Hammond Manufacturing

PWR XFMR SEMI-TORO 40VA TH

2

266G36

266G36

Hammond Manufacturing

PWR XFMR LAMINATED 18VA CHAS MT

13

166M8

166M8

Hammond Manufacturing

PWR XFMR LAMINATED 25.5VA CHAS

10

363AX

363AX

Hammond Manufacturing

PWR XFMR LAMINATED 32VA CHAS MT

4

278CX

278CX

Hammond Manufacturing

PWR XFMR LAMINATED 454VA CHAS MT

4

182F240

182F240

Hammond Manufacturing

PWR XFMR TORO 80VA CHAS MT

0

186D20

186D20

Hammond Manufacturing

PWR XFMR LAMINATED 30VA CHAS MT

33

369BX

369BX

Hammond Manufacturing

PWR XFMR LAMINATED 39VA CHAS MT

3

1182K110

1182K110

Hammond Manufacturing

PWR XFMR TORO 160VA CHAS MT

44

187D36

187D36

Hammond Manufacturing

PWR XFMR LAMINATED 30.6VA CHAS

5

187A16

187A16

Hammond Manufacturing

PWR XFMR LAMINATED 2.4VA CHAS MT

42

266GD24

266GD24

Hammond Manufacturing

PWR XFMR LAMINATED 16.8VA CHAS

5

186E16

186E16

Hammond Manufacturing

XFRMR LAMINATED 56VA CHAS MOUNT

23

162G28

162G28

Hammond Manufacturing

PWR XFMR LAMINATED 12VA TH

8

167J80

167J80

Hammond Manufacturing

PWR XFMR LAMINATED 80VA CHAS MT

5

162D36

162D36

Hammond Manufacturing

PWR XFMR LAMINATED 1.1VA TH

50

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.

RFQ BOM Call Skype Email
Top