Power Transformers

Image Part Number Description / PDF Quantity Rfq
FP20-125

FP20-125

Triad Magnetics

PWR XFMR LAMINATED 2.5VA TH

704

FP34-340-B

FP34-340-B

Triad Magnetics

PWR XFMR LAMINATED 12VA TH

0

VPP16-1250

VPP16-1250

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

1144284

VPP36-820

VPP36-820

Triad Magnetics

PWR XFMR LAMINATED 30VA TH

21

F-373P

F-373P

Triad Magnetics

PWR XFMR LAMINATED 24VA TH

42

FS48-050

FS48-050

Triad Magnetics

PWR XFMR LAMINATED 2.5VA TH

10

F-3181U

F-3181U

Triad Magnetics

PWR XFMR LAMINATED 50VA CHAS MT

0

F56-650-C2

F56-650-C2

Triad Magnetics

PWR XFMR LAMINATED 36VA TH

0

FS10-250-B

FS10-250-B

Triad Magnetics

PWR XFMR LAMINATED 2.4VA TH

0

F4-48

F4-48

Triad Magnetics

PWR XFMR LAMINATED 6VA CHAS MT

17

VPL16-3100

VPL16-3100

Triad Magnetics

PWR XFMR LAMINATED 50.0VA CHAS

253

FS28-700

FS28-700

Triad Magnetics

PWR XFMR LAMINATED 20VA TH

0

F20-600

F20-600

Triad Magnetics

PWR XFMR LAMINATED 12VA TH

9341

F16-2250-C2

F16-2250-C2

Triad Magnetics

PWR XFMR LAMINATED 36VA TH

0

F56-020

F56-020

Triad Magnetics

PWR XFMR LAMINATED 1.1VA TH

230

F-359XP

F-359XP

Triad Magnetics

PWR XFMR LAMINATED 10VA CHAS MT

9146

TCT40-05E07AB

TCT40-05E07AB

Triad Magnetics

PWR XFMR LAMINATED 40VA CHAS MT

332

FP30-200-B

FP30-200-B

Triad Magnetics

PWR XFMR LAMINATED 6VA TH

0

F6-10

F6-10

Triad Magnetics

PWR XFMR LAMINATED 30VA CHAS MT

0

TCT40-03E07AB

TCT40-03E07AB

Triad Magnetics

PWR XFMR LAMINATED 40VA CHAS MT

224

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.