Power Transformers

Image Part Number Description / PDF Quantity Rfq
12.8-4

12.8-4

Signal Transformer

PWR XFMR LAMINATED 51.2VA CHAS

0

241-4-28L

241-4-28L

Signal Transformer

PWR XFMR LAMINATED 6VA CHAS MT

0

241-3-36L

241-3-36L

Signal Transformer

PWR XFMR LAMINATED 2.4VA CHAS MT

0

16-1

16-1

Signal Transformer

PWR XFMR LAMINATED 16VA CHAS MT

0

DP-241-8-20L

DP-241-8-20L

Signal Transformer

PWR XFMR LAMINATED 100VA CHAS MT

0

DP-241-7-28L

DP-241-7-28L

Signal Transformer

PWR XFMR LAMINATED 56VA CHAS MT

0

241-6-36L

241-6-36L

Signal Transformer

PWR XFMR LAMINATED 30VA CHAS MT

0

SHE-1000

SHE-1000

Signal Transformer

PWR XFMR LAMINATED 1000VA CHAS

0

12.8-6

12.8-6

Signal Transformer

PWR XFMR LAMINATED 76.8VA CHAS

0

DP-241-8-120L

DP-241-8-120L

Signal Transformer

PWR XFMR LAMINATED 100VA CHAS MT

1

DP-241-5-120L

DP-241-5-120L

Signal Transformer

PWR XFMR LAMINATED 12VA CHAS MT

0

DMPC-Y-12

DMPC-Y-12

Signal Transformer

PWR XFMR LAMINATED 24VA TH

0

241-7-28L

241-7-28L

Signal Transformer

PWR XFMR LAMINATED 56VA CHAS MT

2

DMTT-300

DMTT-300

Signal Transformer

PWR XFMR LAMINATED 300VA CHAS MT

0

DP-241-8-28L

DP-241-8-28L

Signal Transformer

PWR XFMR LAMINATED 100VA CHAS MT

0

DP-241-6-10L

DP-241-6-10L

Signal Transformer

PWR XFMR LAMINATED 30VA CHAS MT

0

SHE-2500

SHE-2500

Signal Transformer

PWR XFMR LAMINATED 2500VA CHAS

0

12.8-1

12.8-1

Signal Transformer

PWR XFMR LAMINATED 12.8VA CHAS

0

DP-241-8-56L

DP-241-8-56L

Signal Transformer

PWR XFMR LAMINATED 100VA CHAS MT

0

241-4-56L

241-4-56L

Signal Transformer

PWR XFMR LAMINATED 6VA CHAS MT

0

Power Transformers

1. Overview

Power transformers are static electrical devices that transfer energy between circuits through electromagnetic induction. They enable voltage conversion (step-up/step-down) while maintaining galvanic isolation. These components are fundamental in power distribution systems, renewable energy integration, and industrial equipment, ensuring efficient energy transmission and voltage level adaptation.

2. Main Types and Functional Classification

TypeFunctional CharacteristicsApplication Examples
Distribution TransformersMedium voltage conversion (1kV-36kV), compact designUrban power grids, residential areas
Transmission TransformersHigh voltage (66kV-800kV), grid stability focusSubstations, long-distance power lines
Instrument TransformersMeasurement and protection (CT/VT types)Energy metering, relay protection
Specialty TransformersCustom configurations (furnace, traction, marine)Industrial furnaces, railway systems

3. Structure and Components

Typical construction includes:

  • Core: Grain-oriented silicon steel laminations for magnetic flux path
  • Windings: Primary/secondary copper/aluminum coils with insulation layers
  • Insulation: Mineral oil, synthetic esters, or solid materials (e.g., epoxy)
  • Cooling System: Radiator tanks, fans, or forced-oil circulation
  • Tap Changer: On-load/off-load voltage regulation mechanism
  • Protection: Buchholz relay, pressure relief valves, temperature sensors

4. Key Technical Parameters

ParameterTypical RangeSignificance
Rated Voltage230V-800kVDetermines system compatibility
Power Capacity50kVA-1000MVADefines energy throughput
Voltage Ratio1:1 to 1:20Specifies transformation ratio
Efficiency95%-99.5%Impacts operational costs
Short Circuit Impedance4%-20%Affects fault current limitation
Insulation ClassA (105 C) to C (220 C)Determines thermal endurance

5. Application Areas

Major sectors include:

  • Electricity distribution networks (urban/rural)
  • Renewable energy systems (wind/solar grid-tied inverters)
  • Industrial machinery (CNC, smelters, compressors)
  • Railway traction systems (15kV-25kV conversion)
  • Data centers (HVDC conversion systems)

6. Leading Manufacturers and Products

ManufacturerRepresentative ProductKey Features
Siemens EnergyBlue TransformersEnvironmentally friendly synthetic ester insulation
Asea Brown Boveri (ABB)550kV UHV Transformer 500kV DC transmission capability
General Electric (GE)Premier SeriesSmart monitoring with Predictivity analytics
Mitsubishi Electric330MVA Traction TransformerCompact design for Shinkansen trains

7. Selection Guidelines

Key considerations:

  • Voltage levels (primary/secondary requirements)
  • Load profile (continuous vs. intermittent duty)
  • Cooling requirements (ONAN/ONAF/OFAF modes)
  • Environmental conditions (temperature, altitude, seismic zones)
  • Protection features (IP rating, fire resistance)
  • Smart grid compatibility (IoT sensor integration)

Case Study: Wind farm grid connection selected 33/132kV ONAF-cooled transformer with 12% impedance to meet fault ride-through requirements.

8. Industry Trends

Current development directions:

  • Smart transformers with real-time monitoring (IEEE C57.163 compliant)
  • Amorphous metal core adoption (50% core loss reduction)
  • Hydrogen-cooled systems for offshore applications
  • Modular solid-state transformer (SST) prototypes (DOE GRID DATA initiative)
  • Increased demand for 132kV+ mobile transformers in disaster recovery

Market forecasts indicate 6.2% CAGR through 2030, driven by grid modernization and EV charging infrastructure expansion.